9-6. Procedure for upgrading RISC firmware:
 ・ After preparing the CF card, copy the latest version ( XXXX. BIN) into the root directory.
 ・ Insert the CF card, and select "FIRMWARE VERSION" from the SETUP menu.
 ・ Follow the instructions on screen for version upgrading. It takes approx. 3-4 minutes.
 ・ Check the version of firmware by "RISC VERSION" of the image adjustment software.
 Note:
In case incorrect files are included in the CF card, the details for upgrading are not displayed even
after selecting "FIRMWARE VERSION" from the SETUP menu.
< Measurement of Consumption current value >
When this camera is used for measuring the consumption current value, set the MB-D200 and wire as follows:
Main SW・OFF
All operational buttons are NOT pushed.
Main SW・ON (Half-release timer OFF)
Main SW・ON (Half-release timer ON)
Main SW・ON (Illumination ON)
Main SW・ON (TFT ON)
7.8V 0.3Ω
MB-D200
Test item
- A64 ・
Standard
200 μ A or less
ref. above.
200μA or less
AF50/1.4D、EV12
380 m A or less
400 m A or less
500 m A or less
-
INC
VBA13001-R.3677.A
Test condition

Hide quick links: