Front Body; Metering Fpc Unit; Prism Box Unit - Nikon D200 Repair Manual

Hide thumbs Also See for D200:
Table of Contents

Advertisement

2. Front body

Metering FPC unit

Prism box unit

(with prism and eyepiece)
・ Remove the metering FPC from the connector of the SI-
FPC (#1005).
・ Take out three screws (#883), and remove the metering
FPC unit (#B10006).
・ Three springs (#884) come off.
・ Take out two screws (#1617) and remove the metering
FPC unit pedestal (#B882).
Caution:
The screw (#883) is attached with the
adhesive.
In case the screw (#883) is moved, the
AECCD positioning adjustment (ref.
Assembly) becomes necessary.
- D22 ・
-
INC
VBA13001-R.3677.A