2. Front body
Metering FPC unit
Prism box unit
(with prism and eyepiece)
・ Remove the metering FPC from the connector of the SI-
FPC (#1005).
・ Take out three screws (#883), and remove the metering
FPC unit (#B10006).
・ Three springs (#884) come off.
・ Take out two screws (#1617) and remove the metering
FPC unit pedestal (#B882).
Caution:
The screw (#883) is attached with the
adhesive.
In case the screw (#883) is moved, the
AECCD positioning adjustment (ref.
Assembly) becomes necessary.
- D22 ・
-
INC