4. Separation of Front body from Rear body

・Remove the solder bridge at two places on the power drive PCB (#B1002).
Remove the solder bridge at two places on the power drive PCB (#B1002).
・Unsolder the wires (Black/Gray) of the mount GND.
Unsolder the wires (Black/Gray) of the mount GND.
・Unsolder the wires (Black/Red) of the SQ motor.
Unsolder the wires (Black/Red) of the SQ motor.
・Unsolder the wires (Black) of the buzzer unit.
Unsolder the wires (Black) of the buzzer unit.

Eyepiece mold

・Take out the two screws (#615).
Take out the two screws (#615).
・Remove the sponge (#752), the eyepiece mold (#291), and the sponge (#779).
Remove the sponge (#752), the eyepiece mold (#291), and the sponge (#779).
Solder bridges
Wire× 2 (Black/Red) of SQ motor
Screw (#615) × 2
Sponge (#752)
- D40 ・ D90 -
Wire× 2 (Black/Gray) of the mount GND
Wire× 2 (Black) of the buzzer unit
Eyepiece mold (#291)
Sponge (#779)