7. Machine installing procedure

A. Setting related to process
1) Open the left door and the front door.
2) Remove the developer cartridge from the machine.
3) Remove the top cover of the developer cartridge.
4) While rotating the MG roller, supply developer into the devel-
oper cartridge evenly.
Note that the MG roller must be rotated in the arrow direction
as shown in the figure below.
Use of a metal scale or a screwdriver (-) facilitates the proce-
dure.
Note: Before opening the developer seal, shake it 4 or 5 times.
Y105220-6
5) Attach the top cover to the developer cartridge and install the
cartridge to the machine.
B. Toner cartridge settings
1) Remove a new toner cartridge from the package and shake it
horizontally five or six times.
2) Insert a new toner cartridge.
Push the cartridge in until it locks securely into place.
3) Gently remove the sealing tape from the cartridge.