4) Return the cartridge lock lever.
C. Setting related to fusing
1) Put down the right and the left levers of the fusing unit in the
arrow direction.
D. Paper setting
1) Pull out the first stage paper feed tray.
Slowly pull out the tray until it stops.
6-12
2) While pressing the paper holding plate, remove the fixing pin.
3) Put paper in the tray, and close the paper feed tray.

8. Automatic developer adjustment

1) Attach the cabinets which were removed.
2) Close the left door.
At that time, keep the front door open.
Note: The automatic developer adjustment must be performed by
entering the simulation mode with the front door open. If the
power is turned on with the front door closed, warm-up is
performed to supply toner to the developing unit. As a
result, the reference toner density cannot be obtained.
3) Insert the power plug into the power outlet.
4) Go through the modes specified in Simulation 25-2.
5) Close the front door.
(LCD Display)
SIMULATION 25-2
AUTOMATIC DV ADJUSTMENT. PRESS START.
HUMIDITY AREA:
TEMPERATURE AREA:
DEVE REFERENCE:
Press [START] key.
SIMULATION 25-2
AUTOMATIC DV ADJUSTMENT. EXECUTING···.
HUMIDITY AREA:
TEMPERATURE AREA:
DEVE REFERENCE:
Service Manual
70.0
-
72.5
70.0
-
72.5
128
Press [CUSTOM SETTINGS] key, and the
operation is stopped immediately or after 2 min.
70.0
-
72.5
70.0
-
72.5
118