Olivetti d-Copia 3501 Service Manual page 93

Hide thumbs Also See for d-Copia 3501:
Table of Contents

Advertisement

No.
Name
1
Laser control PWB
2
Cylindrical lens
3
Incidence reflection mirror
4
No. 1 mirror
5
fθ lens 1
6
fθ lens 2
7
BD PWB
8
No. 2 mirror
9
Plane lens
10
Convergence lens for BD
C. Operational descriptions
[Laser optical path]
∗ The LSU must not be disassembled in the market.
(1) Polygon motor
Number
Model
of mirrors
31/35PPM
14
17000RPM
45PPM
14
22000RPM
(2) Outline of LSU specifications
Effective scan width: 297mm
Resolution:
600dpi
Main scan = 60 - 85 µm
Beam diameter:
Sub scan = 75 - 110 µm
Laser power:
0.23±0.01mW (45 PPM)
0.19±0.01mW (35 PPM)
LD wave length:
770 - 795nm
D. Maintenance and parts replacement
No.
Unit
a
1
a-1
7-44
Controls laser beam flashing and the output value.
Converges laser beams to focus.
Assures the optical path for laser beams.
Assures the optical path for laser beams.
Deflects laser beams so that the laser scan speeds on the both ends of the drum and that at the
center of the drum are the same.
Detects the timing of laser scan start. This device is used to detect a laser trouble.
Converges laser beams to focus.
Assures the optical path for laser beams.
Converges laser beams onto the BD PWB.
RPM
Bearing
OIL
Superior in
silence.
OIL
Parts
LSU
Function
a-1. LSU
1) Remove the screw, and remove the right cabinet.
2) Remove the screw, and remove the right noise cover.
3) Remove the connector, and remove the screw.
Service Manual
Y105220-6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-copia 3501mfD-copia 4501D-copia4501mf

Table of Contents