System Trouble Event Listing; How System Troubles Are Displayed - Bosch Solution 16i User Manual

Hide thumbs Also See for Solution 16i:
Table of Contents

Advertisement

Solution 16
User Guide
i
Syste m Tro u ble Eve nt Li st in g
When one or more trouble events are in effect, the keypad will display the SERVICE symbol indicating that something
requires attention. The table below lists all of the system troubles or system faults which can be present on the alarm panel.
Each trouble event that can be shown by the panel has been assigned a unique Trouble Event Number. This number is
used to identify the trouble event from the list shown in "Table 24: System Trouble / Fault Descriptions" on page 35.
To interpret the system trouble from the keypad do the following;
1) Enter program mode and then press [7] + [0] + [1] + [OK]. Alternatively you can press the [] at any time provide a
system trouble is present. The keypad will now show the first trouble event number in the display. Use the the [] and []
keys to scroll from one trouble event to the next.
2) To find out more detail on each specific trouble event you can either refer to the trouble event descriptions in the table
below or to view more specific information on the keypad press [OK] and the display will begin to scroll the trouble event
number, the device or module number, trouble text description 1 and then trouble text description 2. The display will
continure to scroll the description of the trouble event which is in focus.
3) To return to the trouble list, press the [MENU] key or the exit completely and return to normal state press and hold the
the [MENU] key down for 2 seconds.

How System Troubles Are Displayed

The following diagram shows the typical procedure and keypad displays for a panel with 3 system troubles. The trouble
shown are Panel Tamper, Panel AC Fail and Panel Date and Time Error.
Enter programming mode and then press MENU 7-0-1 + [OK]
F40-1
Press [] or []
F41-1
Press [] or []
F45-1
Press [] or []
End
Trouble Event Number
F00-Output #
F01-Output #
F02-Output #
F10-Zone #
F11-Zone #
F12-Zone #
F13-Zone #
F20-Zone Expander #
F21-Zone Expander #
F30-Keyfob #
F40-Panel #
F41-Panel #
F42-Panel #
F43-Panel #
F44-Panel #
F45-Panel #
F46-Panel #
F47-Panel #
34
Press [OK]
P001
Press [OK]
P001
Press [OK]
P001
Trouble Event
Description
Output Missing
Output Overload
Output Trouble
Zone Missing
Zone Tamper
Zone Sensor Watch
Zone Low Battery
Zone Module Expander Missing
Zone Module Expander Tamper
RF Keyfob User Low Battery
Panel Tamper
Panel AC Fail
Panel Low Battery
Panel Missing Battery
Panel Default PIN
Panel Date/Time
Panel Route 1
Panel Route 2
cASE
Scrolling
nO AC
Scrolling
cLOc
Scrolling
Device or
Module Number
OP00x
OP00x
OP00x
Zn0xx
Zn0xx
Zn0xx
Zn0xx
IE001
IE001
KF0xx
P001
P001
P001
P001
P001
P001
P001
P001
OPEn
ErrOr
Trouble Text
Trouble Text
Description #1
Description #2
LOst
LOAd
Short
NO
LOAd
LOst
cAse
Open
SEnSOr
ALErt
bAttry
LEvEl
LOSt
cASE
OPEn
LO
BAt
cASE
OPEn
NO AC
bAttry
LEvEl
NO
bAttry
dFAult
PIN
clOc
ErrOr
rEPOrt
rtE 1
rEPOrt
rtE 2
Bosch Security Systems 6/09 BLCC500U FTR1.03