Chime On/Off

Chime mode allows you to monitor a zone (or group of
zones) while the system or area is in the disarmed state.
The system can be programmed to sound the keypad
buzzer or activate a programmable output when the
corresponding chime zone(s) are faulted. This feature can
be useful when you need to monitor the front or back
entrance to the premises.
This menu allows a user to turn chime mode on and off.
Only keypads programmed to sound the chime tone will
be heard when a zone programmed for chime is faulted.
The master user can program which zones are monitored
for chime alarms in MENU 3-0-3.
1. Enter your Master PIN + [MENU].
2. Enter [2] + [0] + [5] + [OK].
The system will display the current chime state. If your
system has been configured for multiple areas you will
be prompted to enter the area number to program.
In the example below chime mode " IS OFF".
3. To turn Chime mode on, simply press the [ON] key.
The display will show that chime mode "IS ON" and
also the chime icon will be displayed.
To toggle chime mode off again, simply press [OFF].
4. Press the [OK] key to exit.
It is possible to turn chime mode on and off pressing
i
the 4 key down for 2 seconds. Only the area currently
Note
in focus will operate when using this method.
Bosch Security Systems 6/09 BLCC500U FTR1.03
chOnOF
MENU 2-0-5
iS OFF
iS ON
Areas > Commands >

Chime Mode

Chime mode allows the master user to control the way
chime alarms operate. There are 4 options available.
1) Chime Always
Will sound the chime alarm while ever the zone(s)
programmed for Chime are open or faulted.
2) Chime One-Shot (Max 255 seconds)
Will sound the chime alarm for the programmed time
regardless of how long the chime zone(s) remains open or
faulted.
3) Delayed Chime (Max 255 seconds)
Will sound the chime alarm only after the chime zone(s)
has been open or faulted for the programmed time.
4) Chime Latching.
Will sound the chime alarm until a valid user code is entered
followed by the [OK] key. This will reset the Chime Alarm.
To set the chime mode.
1. Enter your Master PIN + [MENU].
2. Enter [2] + [0] + [6] + [OK].
If your system has been configured for multiple areas,
your keypad will prompt you to enter the area number
to program. The keypad will display the current chime
mode set for that area.
3. Use the [↑] and [↓] keys to select the required chime
mode.
If a time parameter is required for the chosen mode,
simply enter the require value in seconds.
4. Press [OK] to save and exit, or press [MENU] to exit