Internal Siren Test; Strobe Test; Communication / Reporting; Call/Answer Ras - Bosch Solution 16i User Manual

Hide thumbs Also See for Solution 16i:
Table of Contents

Advertisement

Outputs > Output Testing >

Internal Siren Test

This menu allows you to test any internal sirens which
have been connected to the system. The test will last for 3
seconds.
1. Enter your Master PIN + [MENU].
2. Enter [4] + [9] + [1] + [OK].
If your system has been configured to have more than
one area, the keypad will display the A = prompt.
3. Enter the Area number in which to test the internal
sirens in and then press [OK].
ALARM
The keypad will display 'Bell' and the alarm icon during
the audible 3 second internal siren test.
Outputs > Output Testing >

Strobe Test

This menu allows you to test the external strobe lights
fitted to the system. The test will last for 1 minute.
1. Enter [Master PIN] + [MENU]
2. Enter [4] + [9] + [2] + [OK].
If your system has been configured to have more than
one area, the keypad will display the A = prompt.
3. Enter the area number in which to test the strobe
lights in and then press [OK].
During the 60 second strobe test, the keyapd will
display both the word 'Strobe' and also the alarm icon.
Bosch Security Systems 6/09 BLCC500U FTR1.03
TSTint
MENU 4-9-1
A=
BELL
TStStr
MENU 4-9-2
A=
StrObe
ALARM

Communication / Reporting

Programming options in this section relate to how your
control panel will communicate alarm information. Your
installer will advise you on the configuration of your system.
Comms > Commands >

Call/Answer RAS

This menu allows you to initiate a modem call to the
installer's off-site computer for programming changes and
updates or to remotely service and configure your system.
You should not enter this command unless requested to
do so.
1. Enter your Master PIN + [MENU].
2. Enter [5] + [0] + [1] + [OK].
Comms > Commands >

Call Forward On/Off

This menu allows you to turn on and off the call forward
feature. When you turn on call forwarding, the control
panel will automatically activate and de-activate the call
forward on and call forward off sequence accordingly
when you turn your system All On and Off.
For this feature to work you will need to also program the
Call Forward On and Call Forward Off Numbers as detailed
later in this section.
1. Enter your Master PIN + [MENU].
2. Enter [5] + [0] + [2] + [OK].
If call forwarding is off, the keypad will display:
If call forwarding is on, the keypad will display.
3. To turn Call Forwarding On, press the [ON] key or
press the [OFF] key to turn call Forwarding off.
4. Press [OK] to exit.
Solution 16
User Guide
i
cAlAns
MENU 5-0-1
cfOnOf
MENU 5-0-2
IS OFF
IS ON
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents