Clearances; Non-Combustible Requirements - Regency Fireplace Products Gem54-NG Owners & Installation Manual

Gem54 series gas fireplace
Table of Contents

Advertisement

installation
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest
importance that this fireplace and vent system be installed only in accordance with these instructions.
caution Requirements
The top, back and sides of the fireplace are defined by
standoffs. The metal ends of the standoff may NOT be
recessed into combustible construction.
clearance:
A: Mantel Height (min.)
b: Sidewall
C: Ceiling
(room and/or alcove)
D: Mantel Depth (max.)
E: Alcove Width
F: Alcove Depth
Note
D
A
G
8

clEARANcES

Dimension
20" (508mm)
Top of Fireplace Opening
4" (102mm)
Side of Fireplace Opening
40-7/8" (1038mm)
Top of Fireplace Opening
13" (330mm)
30" Above Fireplace Opening
83" (2108mm)
Sidewall to Sidewall (Minimum)
36" (914mm)
Front to Back Wall (Maximum)
0"
No hearth required
F
B
E
Installed Close
to Floor

NON-COMBUSTIBLE REqUIREMENTS

Wood Stud
4"
(102mm)
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this fireplace and vent
system be installed only in accordance with these instructions.
Measured From:
C
Metal Stud (header)
60-1/2" (1537mm)
Non-combustible
Material
52-5/8"
Non-combustible Material
WARNING
Fire hazard is an extreme risk
Flue clearances
Horizontal - Top
Horiztonal - Side
Horiztonal - Bottom
Vertical
B
Installed Close
to Ceiling
Wood Stud
5-11/16"
(144mm)
Regency Gemfire™ Gas Fireplace
3" (76mm)
2" (51mm)
2" (51mm)
2" (51mm)
F