Warning
Fire or explosion Hazard
failure to follow safety warnings exactly could result in serious
injury, death, or property damage.
- Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch: do not use any phone in your building.
Leave the building immediately.
• Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Tested by:
Certified to/Certifié pour : ANSI Z21.88-2019
920-671
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
Regency ® Gi33LE
Gas Insert
Natural Gas
CSA 2.33-2019
CSA 2.17-2017
Gi33LE-LP
Propane
Installer: Please complete the details on the back cover and
leave this manual with the homeowner.
Homeowner: Please keep these instructions for future
reference.
Owners &
Installation Manual
www.regency-fire.com
07.24.23

Advertisement

Table of Contents
loading

Summary of Contents for Regency Fireplace Products Gi33LE

  • Page 1 Regency ® Gi33LE Owners & Installation Manual Gas Insert www.regency-fire.com MODELS: Gi33LE-NG Natural Gas Gi33LE-LP Propane Warning Fire or explosion Hazard failure to follow safety warnings exactly could result in serious injury, death, or property damage. - Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.
  • Page 2 The Regency gas insert series of handcrafted appliances is designed to provide you with all the warmth and charm of a fireplace at the flick of a switch. The Gi33LE is approved by Intertek for safety and efficiency. As it also bears Regency’s mark, it promises economy, comfort, and security for many trouble-free years to come.
  • Page 3: Table Of Contents

    table of contents Dimensions Mantel Deflector Installation ............59 Premium Faceplate Surround Installation ........60 Traditional Faceplate Surround Install (Part #391-927, 391-928) ..61 Unit Dimensions ................4 Faceplate Dimensions ..............5 Hearth Trim Installation - Trimming to Height ........ 62 Hearth Trim Installation - Mounting Hearth Trim ......
  • Page 4: Unit Dimensions

    dimensions Unit Dimensions Note: Gas Located on left side of appliance and electrical located on the right hand side of appliance. Letter Description Dimensions Dimensions Letter Description Dimensions Dimensions (inches) (mm) (inches) (mm) Width 33-7/8" 860 mm Gas Inlet Front Depth 13-5/16"...
  • Page 5: Faceplate Dimensions

    dimensions Faceplate Dimensions Three-Sided Faceplate Four-Sided Faceplate Dimensions Faceplate Width Height Depth Bottom Height Regular Faceplate 46-5/16" (1176 mm) 30-7/8" (784 mm) 1-5/16" (33 mm) Regular Faceplate w/ Premium 46-3/4" (1188 mm) 31-1/8" (790 mm) 1-11/16" (43 mm) Surround Flush Faceplate 46-1/8"...
  • Page 6: Owner's Information

    Copy of Safety Label A copy of the label that accompanies each Gi33LE gas insert is below. Regency units are constantly improving. Check the safety Duplicate Serial number/Copie No de série Gi33LE Serial Label label on the unit and if it is different from the copy provided DO NOT REMOVE THIS LABEL / Listed: VENTED GAS FIREPLACE HEATER/FOYER AU GAZ À...
  • Page 7: Gas Installation Checklist

    installer's information Gas Installation Checklist REGENCY GAS INSTALLATION CHECKLIST This general checklist does not contain all pertinent installation details or specifics and does not supersede the guidelines in this manual. Your Regency dealer/installer should use it in conjunction with manual instructions. Please follow all local codes and jurisdictions in authority. Customer: Date Installed: Install Address:...
  • Page 8 installer's information REGENCY GAS INSTALLATION CHECKLIST Finishing If applicable, is only noncombustible material installed in the noncombustible areas? Do clearances meet installation and manual requirements? Do the mantels and/or projections comply with the installation manual? If applicable, was the solid fuel fireplace warning plate installed? Appliance Media Setup Do commands from the remote or wall switch light the pilot and main burner? Are the burner media/log set, glass door, and screen installed per instructions in the manual?
  • Page 9: Know Your Appliance

    owner's information Know Your Appliance LETTER DESCRIPTION MORE INFO ON PAGE SCREEN ON/OFF SWITCH 10, 65 GLASS DOOR 54, 67 REMOTE SYNC SWITCH IFC BOARD/WIRING DIAGRAM 11-15 BATTERY BACKUP HOLDER VALVE STEPPER MOTOR GAS SHUT-OFF VALVE AIR SHUTTER ADJUSTMENT ARM Gi33 Direct Vent Gas Insert |...
  • Page 10: Important Message

    Pressures over 1/2 psig, the pipe to the unit must YOUR WARRANTY AND MAY CAUSE be disconnected. The Gi33LE gas insert must be installed in A SERIOUS HOUSE FIRE. accordance with the instructions in this manual; read them carefully before installing the unit. Consult Gas Max.
  • Page 11: Lighting Procedure

    owner's information Lighting Procedure IMPORTANT: The remote control system supplied with this appliance must Note: The first try for ignition will last approximately 60 seconds. If there is no be used for lighting with the ON/OFF key on the hand held transmitter. Prior to operating this appliance, please read the remote control operat- flame ignition (rectification) the board will stop sparking for approximately ing instructions (packaged with remote control) to understand how to...
  • Page 12 owner's information Temperature indication Display Remote-Flame Control With the system in the "OFF" position, press the Thermostat Key and the The Proflame has six (6) flame levels. With the system on, and the flame Mode Key at the same time. Look at the LCD screen on the transmitter level at the maximum in the appliance, pressing the Down Arrow Key to verify that a C or F is visible to the right of the room temperature once will reduce the flame height by one step until the flame is turned off.
  • Page 13 owner's information Smart Thermostat (Transmitter Operation) Remote dimmer control (Light) The auxiliary function controls the AUX power outlet by the dimmable light control. To activate this function use the Mode Key (fig. 1) to index The Smart Thermostat function adjusts the flame height in accordance to the AUX icon (fig.
  • Page 14 owner's information Continuous Pilot/Intermittent Pilot (CPI/IPI) Key Lock selection This function will lock the keys to avoid unsupervised operation. To activate this function, press the MODE and UP Keys at the same Note: Power vent models do not have a Continuous time (fig.
  • Page 15: Proflame Ii Remote Control Operating Instructions

    owner's information Proflame II Remote Control Operating Instructions IMPORTANT:The Proflame Transmitter 2 is an integrated part of the TECHNICAL DATA Proflame 2 System, which consists of these elements: REMOTE CONTROL • Proflame 2 Transmitter, to be used in conjunction with: •...
  • Page 16: Remote/Receiver Coding

    owner's information Remote / Receiver Coding The remote control is coded at the factory. If for what ever reason , the remote requires to be recoded follow steps below. To code the receiver to the hand-held remote, follow the procedure below. 1.
  • Page 17: Copy Of Lighting Plate Instructions

    owner's information Copy of Lighting Plate Instructions FOR YOUR SAFETY READ BEFORE LIGHTING POUR VOTRE SÉCURITÉ – À LIRE AVANT LA MISE EN MARCHE WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 18: Installer's Information

    Must be removed: 3. The appliance should be inspected before use 1 -Damper The Gi33LE gas insert was tested and approved and at least annually by a professional service 2- Grate (with log set) for venting into any masonry or approved solid person.
  • Page 19: Installation Checklist

    installer's information Installation Checklist Minimum Fireplace Dimensions Before installing the vent system, ensure that the The minimum fireplace clearances & dimensions for the Regency gas insert are shown in the following damper plate is open and secure to prevent it from diagram: falling and crushing the liner.
  • Page 20: Minimum Fireplace Opening Sizes With Varying Faceplate/Backing Plate Options

    installation Minimum Fireplace Opening Sizes with Varying Faceplate/Backing Plate Options Dimensions Minimum Install Minimum Install Minimum Install Minimum Rear Taper Depth Faceplate Width Height Depth Width Regular Faceplate 33" (838 mm) 24" (610 mm) 18" (457 mm) 22-3/8" (568 mm) 3-1/2"...
  • Page 21: Minimum Clearances To Combustibles

    installation Minimum Clearances to Combustibles The clearances listed below are minimum distances unless otherwise stated. A major cause of fires is failure to maintain required clearances (airspace) to combustible materials. It is of the greatest importance that this appliance is installed only in accordance with these instructions.
  • Page 22: 3-1/2" Mantel Deflector

    installation Mantel Clearances Without Mantel Deflector Mantel Clearances with 3-1/2" Mantel Deflector 30" 30" 28" 28" 26" 26" 24" 24" 22" 22" 20" 20" 18" 18" 16" 16" 14" 14" 12" 12" 10" 10" 8" 8" 6" 6" Deflector 4" 4"...
  • Page 23: Using Steel Studs And Concrete Board Over Masonry Brick Fireplace

    installation Using Steel Studs and Concrete Board Over Masonry Brick Fireplace The masonry front brick facing can be removed and replaced with non-combustible materials such as steel studs and concrete board/dura rock/micor board as per diagram 1, only if safe to do so. Steel stud may also be placed in front of the masonry brick if left in place. This is the preferred method depending on the condition of the masonry brick fireplace.
  • Page 24: Leveling Legs Adjustment

    installation Leveling Legs Adjustment The leveling of the appliance must be done prior to hooking up gas line and vent system. 1. The leveling bolts can be installed with bolts from above or below 4. The front leveling bolts can be accessed from the front of the insert, on (preferred method) to level the appliance.
  • Page 25: Gas Connection

    installation Gas Connection Only people licensed to work with gas piping may make the gas connections to this appliance. 1. If the appliance is installed into an existing chimney system, thoroughly clean the masonry or factory-built fireplace. 2. The appliance has an opening on the left side of the control compartment. A 3/8”...
  • Page 26: Alternate Approved Vertical Termination Caps

    installation Alternate Approved Vertical Termination Caps Alternate Approved Caps Option 1 46DVA-CL34 - Vertical High Wind Cap With Flashing. Also includes 3" (76 mm) x 35' (10.7 m)Air Inlet Liner & 4" (102 mm) x 35' (10.7 m)Exhaust Liner Option 2 46DVA-34CLTA Chimney Liner Conversion From Co-linear To Co-Axial (Includes Flashing) 46DVA-VCH Vertical High Wind Cap Note: Both Air Inlet/Exhaust Liners Would Need To Be Purchased Separately with Option 2 as they are not included.
  • Page 27: Restrictor Adjustment

    installation Restrictor Adjustment Tools needed • Phillips screwdriver Gently lift the screen assembly up and out. Refer to the Screen Removal section. Remove the glass door. Refer to the Glass Door Removal section. Refer to the vent chart to determine the restrictor setting. Locate the restrictor plates and screws.
  • Page 28: Vertical Venting/Restrictor Settings For Ng And Lp

    installation Vertical Venting/Restrictor Settings for NG and LP Set 4 Set 3 2.5" open 3.0" open Set 2 Set 1 3.5" open 4.25" open Aeration 3/16” Aeration 5/16” | Gi33 Direct Vent Gas Insert...
  • Page 29: Horizontal Co-Linear Vent Kit (Masonry Fireplaces Only)

    installation Horizontal Co-Linear Vent Kit (Masonry Fireplaces Only) APPLICATION This instruction applies to the DuraVent Direct Vent Pro termination system and is intended as a supplement to the applicable Direct Vent Pro instruc- tions. This termination and venting system and the gas appliance were tested and listed by an accredited test agency. Kit # 46DVA-HCL34 includes: 1 Horizontal Termination Cap Two 10' (3 m) long;...
  • Page 30: Flue Collar Installation/Removal

    installation Flue Collar Installation/Removal 1. Detach the flue collar from the unit by removing the screws and sliding 4. The tabs on the insert will seal the flue collar against the intake inlet the plate backward. and exhaust outlet. Secure with the two screws removed in step 1. Connector plate screws 2.
  • Page 31: Air Shutter Adjustment

    - Pull out to close air shutter + Pull in to open the air shutter Unit Fuel Type Min. Air Shutter Setting* Gi33LE 3/16" (5 mm) Gi33LE 5/16" (8 mm) *At higher elevations, air shutter settings may have to be opened more to compensate.
  • Page 32: Ng System Data

    installation Pilot Adjustment 885 S.I.T. Valve Description NG System Data Min. Supply Pressure 5" WC (1.25kPa) Periodically check the pilot flames. Correct 1. 6 Stage flame adjustment flame pattern has two strong blue flames: 2. Pilot adjustment Low Setting Man. 1.1 WC (0.27 kPa) 1 flowing around the flame sensor and 1 Pressure...
  • Page 33: Gas Shut Off Procedure

    installation Gas Shut Off Procedure Slide the shut-off arm out. Slide shut-off arm back in. Turn gas valve to desired position. If needed, use a flathead screw- driver to turn valve. CLOSED OPEN Alternatively, rotate the knob to turn it into a handle for more lever- age.
  • Page 34: Conversion From Natural Gas To Propane

    Conversion Kit # 391-969 from NG to LPG Conversion from Natural Gas to Propane for Gi33LE using SIT 885 NOVA Gas Valve THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 11. Remove tray fastener by removing 1...
  • Page 35 Gi33LE LP Conversion installation 14. Reverse steps 7 to 2. 15. Attach the "This unit has been converted to LPG" label near or on top of the serial decal. 16. Replace the yellow "Natural Gas" label with the red "LPG" label. 17. Adjust the aeration settings - see the "Air Shutter Adjustment" section in themanual. 18. Start the appliance (see the "Lighting Instructions" section in the manual). Ensure that pilot and burner ignition are completed without delay. Check your inlet and outlet pressures at full load. With a soapy solution, leak test the entire system. Verify correct flame and pilot appearance. Wires must be secured by gray clips when reinstalling. Gi33 Direct Vent Gas Insert | 920-672 07.06.23...
  • Page 36: Panel Installation

    Gi33 Panel Installation installation (Part # 391-901, 391-903, 391-904, 391-905, 391-906, 391-907) Panel Installation PANEL INSTALLATION These instructions are for use with the following products: 2. Remove two screws securing the blocker and uninstall blocker before installing any panels. Part # Description 391-901 Brick Panel Standard Brown...
  • Page 37 Gi33 Panel Installation installation (Part # 391-901, 391-903, 391-904, 391-905, 391-906, 391-907) For brick/steel/glass panels: 5. Insert the left panel and push until it touches the rear panel. 6. Insert the right panel and push until it touches the rear panel. 7.
  • Page 38 Gi33 Panel Installation installation (Part # 391-901, 391-903, 391-904, 391-905, 391-906, 391-907) 9. Reinstall the blocker and secure using the previously removed screws. 8. Install the front panel(s)* by placing between the front of the firebox and the media tray. •...
  • Page 39: Birch & Oak Log Set Installation (Part #311-931 & 311-934)

    installation Birch & Oak Log Set Installation (Part # 311-931 & 311-934) Birch & Oak Log Set Installation (Part #311-931 & 311-934) Read the instructions below carefully and refer to the images. If the logs are broken, do not use the unit until they are replaced.
  • Page 40 Birch & Oak Log Set Installation installation (Part # 311-931 & 311-934) 2. Install the log grate with the two screws provided. 4. Fill the media tray with the 3/4” glass, then scatter the black sea vermiculite on top. The glass can cover parts of the front brick panel. Not all media is used in the install, there will be leftover glass and embers.
  • Page 41 Birch & Oak Log Set Installation installation (Part # 311-931 & 311-934) 6. Carefully lay Log 1 on the two pins behind the burner. Make sure the left part of the log does not hit the left portion of the burner. Log 1 The Birch log set (311-931) will look slightly different than shown in the pictures, but the numbering is the...
  • Page 42 Birch & Oak Log Set Installation installation (Part # 311-931 & 311-934) 8. Place Log 3 on the pin and rotate it until it touches the tab shown below. Ensure that Log 3 is resting directly on the tray with no embers underneath. Log 3 9.
  • Page 43 Birch & Oak Log Set Installation installation (Part # 311-931 & 311-934) 10. Place Log 5 on the pin under the right burner. Log 5 11. Place Log 6 on the grate with the notch on the middle of the log sitting on the first grate bar and the flat section pointing up. Log 6 does not sit on the front panel - it rests on the tab next to the second grate bar.
  • Page 44 Birch & Oak Log Set Installation installation (Part # 311-931 & 311-934) 12. Place Log 7 with the notch (shown below) resting on the upper right corner of the second grate bar. Rest the bottom right end of the log on the front panel, ensuring it does not protrude over the bottom edge of the firebox and that there are no embers underneath.
  • Page 45 Birch & Oak Log Set Installation installation (Part # 311-931 & 311-934) 14. Place Log 9 on the right end of the burner. The log rests on the burner, not on the fifth grate bar. Log 9 15. Place Log 10 on the left side of the burner. Log 10 should not touch Log 6. Readjust the positioning of Log 6 if necessary, enuring it is resting on the tab beside the second grate bar.
  • Page 46 Birch & Oak Log Set Installation installation (Part # 311-931 & 311-934) Log 1 Log 2 Log 3 Log 10 Log 9 Log 4 Log 5 Log 8 Log 6 Log 7 Final Placement | Gi33 Direct Vent Gas Insert...
  • Page 47: Driftwood Log Set Installation (Part #311-930/P)

    installation Driftwood Log Set Installation (Part # 311-930/P) Driftwood Log Set Installation (Part #311-930/P) Read the instructions below carefully and refer to the images. If the logs are broken, do not use the unit until they are replaced. Improper positioning of the logs and may create carbon build-up and can alter the unit's performance.
  • Page 48 installation Driftwood Log Set Installation (Part # 311-930/P) 2. Remove pilot shield. 6. Remove the burner by sliding left and up out of the burner tray. 7. Install the Front Log Mount with one screw as shown. 3. Remove 3 screws attaching the pilot shield to the burner tray. 4.
  • Page 49 installation Driftwood Log Set Installation (Part # 311-930/P) 9. Fill the glass tray with 3/4" glass until it is full. 10. Fill the outside of the Burner Tray and around the Glass Tray with Black Embers as shown. Do not fill the sides of the firebox past the Burner Tray.
  • Page 50 installation Driftwood Log Set Installation (Part # 311-930/P) 12. Carefully lay Log 1 on the two pins behind the burner. Make sure the left part of the log does not hit the left portion of the burner. Log 1 13. Place Log 2 behind the left portion of the burner, resting its right side in the notched area on Log 1. Rotate the front of Log 2 onto the metal flange and ensure it is resting directly on the tray, with no embers underneath.
  • Page 51 installation Driftwood Log Set Installation (Part # 311-930/P) 15. Place Log 4 on the two pins under the left burner. Log 4 16. Place Log 5 on the pin under the right burner. Log 5 17. Place Log 6 on the right end of the burner. The log rests on the burner. Log 6 Gi33 Direct Vent Gas Insert | 06.26.23...
  • Page 52 installation Driftwood Log Set Installation (Part # 311-930/P) 18. Place Log 7 on the left of the burner. The log rests on the burner. Log 7 19. Place Log 8 on the pin on the front log mount. The other end will rest on the ember media. Log 8 NOTE: IGNORE TAB UNDER BURNER TRAY, THIS IS...
  • Page 53 installation Driftwood Log Set Installation (Part # 311-930/P) LOG #1 LOG #7 LOG #2 LOG #6 LOG #3 LOG #4 LOG #5 LOG #8 Final Placement Gi33 Direct Vent Gas Insert | 06.26.23 920-621a...
  • Page 54: Screen Removal

    installation Screen Removal 1. Gently lift screen assembly out. 2. Place screen assembly where it will not be scratched or broken. | Gi33 Direct Vent Gas Insert...
  • Page 55: Glass Door Removal

    installation Glass Door Removal 1. Locate and remove the four forward-facing Phillips head screws in the locations shown. 2. Lift glass door up and out. 3. Place glass door in a safe place where it will not be scratched or broken. Gi33 Direct Vent Gas Insert |...
  • Page 56: Faceplate/Finishing Trim Installation

    Gi33 Faceplate Installation installation Faceplate/Finishing Trim Installation FACEPLATE INSTALLATION 3. Fasten the four screws on both sides to attach the faceplate/finishing These instructions are for use with the following products: trim. Part # Description 391-910 Faceplate Regular 3-Sided Black 391-912 Faceplate Flush 3-Sided Black 391-913 Faceplate Flush 4-Sided Black...
  • Page 57: Backing Plate Installation

    installation Gi33 Backing Plate Installation Backing Plate Installation ?. Remove the four screws located at the front of the unit. These instructions are for use with the following products: 4. Remove the four screws at the front of the unit. Part # Description 391-936...
  • Page 58 Gi33 Backing Plate Installation installation 8. Pull the backing plate as far forward as possible against the faceplate, then retighten the screws on both sides. 9. Install the compact screen. | Gi33 Direct Vent Gas Insert 920-688 05.25.23...
  • Page 59: Mantel Deflector Installation

    installation Gi33 Mantel Deflector Installation (Part #391-940) Mantel Deflector Installation 1. Fasten the three screws provided from the back to attach the 3. Install the compact screen. mantel deflector. 2. Mantel deflector installed. Gi33 Direct Vent Gas Insert |...
  • Page 60: Premium Faceplate Surround Installation

    installation Gi33 Premium Faceplate Surround Installation (Part # 391-920, 391-921, 391-922, 391-923, 391-924) Premium Faceplate Surround Installation These instructions are for use with the following products: 3. Ensure the faceplate and faceplate surround are pressed against PART # Description each other. Insert the brackets on both sides, at the bottom. 391-920 Faceplate Surround Black 391-921...
  • Page 61: Traditional Faceplate Surround Install (Part #391-927, 391-928)

    installation Gi33 Traditional Faceplate Surround Installation (Part # 391-927, 391-928) Traditional Faceplate Surround Installation (Part #391-927, 391-928) These instructions are for use with the following products: 4. Tighten the bottom screws (x4). PART # Description 391-927 Traditional Surround Black 391-928 Traditional Surround Brushed Antique Copper Note: Traditional surround fits only the 391-912 3-sided flush faceplate.
  • Page 62: Hearth Trim Installation - Trimming To Height

    installation Gi33 Hearth Trim Installation - Trimming to Height (Part # 391-941) Hearth Trim Installation - Trimming to Height Part can only be installed with the Gi33 Regular Faceplate 391-910 3. Slide the lower section back into the clips on the rear of the upper or Regular Faceplate and Premium Surrounds (391-920/-921/- section.
  • Page 63: Hearth Trim Installation - Mounting Hearth Trim

    installation Gi33 Hearth Trim Installation - Mounting Hearth Trim Hearth Trim Installation - Mounting Hearth Trim 2b. With premium surround: slide the hearth trim as far back as 1. Loosely attach the hearth trim using the slots in the unit's base and possible (careful not to scratch it) and tighten the screws.
  • Page 64: Optional Wall Thermostat

    installation Optional Wall Thermostat Supplied Remote Control A wall thermostat may be installed if desired; follow Use the FPI remote control kit supplied with this the wiring diagram below. FPI offers an optional unit. Use of other systems may void your war- programmable thermostat, but any 250-750 millivolt ranty.
  • Page 65: Wiring Diagram

    installation Wiring Diagram This heater does not require a 120 V A.C. supply for operation. In case of a power failure, the burner switch and the remote control/thermostat will continue to operate on backup battery. However, a 120 V A.C. power supply is needed for the fan/blower operation. •...
  • Page 66: Operation

    operating instructions Operating Instructions Shutdown Procedure On/Off Switch 1. Press the ON/OFF button on the remote Before operating this appliance, proceed through the following checklist. 2. If service is to be performed - you must discon- nect power and shut off gas to the unit. 1.
  • Page 67: Normal Operating Sounds Of Gas Appliances

    operating instructions Normal Operating Sounds of 4. Check the burner’s position and condition pe- 6. Keep the area near the appliance clear and free riodically, as well as the burner flame, making from combustible materials, gasoline, and other Gas Appliances sure it is steady, not lifting or floating.
  • Page 68: Maintenance

    maintenance Door Glass General Vent Maintenance Your Regency insert is supplied with high Conduct an inspection of the venting system -temperature Neoceram glass that will withstand semiannually. Areas to inspect are as follows: the highest heat your unit can produce. If your glass requires cleaning, we recommend using an 1.
  • Page 69: Fan Replacement

    maintenance Fan Replacement • To access the side and rear panels, disconnect the gas and venting (see the venting and flue installation sections in this manual for steps). You cannot access the blower from the front of the appliance. 1. Shut the power off. 2.
  • Page 70: Valve Replacement

    maintenance Valve Replacement Before you begin: • Shut off the gas supply to the unit. • Disconnect all electrical supply to the unit. • Remove door, see glass door removal section for instructions. Always let the appliance cool to room temperature before servicing. When the glass is cold and the appliance is lit, condensation may fog the glass.
  • Page 71 maintenance 7. Disconnect the incoming gas ex line from the ball valve. Slide the pilot wires through the grommet to remove. 5. Disconnect the green, orange and yellow cables from the valve. 7. Disconnect the incoming gas flex line from the ball valve. Slide the pilot 5.
  • Page 72: Light Bulb Replacement

    maintenance Light Bulb Replacement 1. Remove screen, glass door, logs and any other media, log grate, and lower panel (if installed). 2. Remove two (2) screws from light assembly cover in the locations shown below. 3. Lift the light assembly cover out of the way. 4.
  • Page 73: Gas Maintenance - Recommended Annual Routine

    Gas Maintenance maintenance Gas Maintenance - Recommended Annual Routine Recommended Annual Routine Maintenance for Gas Fireplaces, Stoves and Inserts In order for your Regency appliance to continue to provide comfort to your home periodic maintenance must be performed to ensure it is operating at peak efficiency. The items in the list should be checked by a licensed gas service technician during the annual service check. Your unit may require more frequent maintenance checks if you notice any changes in how it operates. Operational changes to look for can include, but are not limited to, extended start up time, increased fan noise, residue/carbon build up, white build up on the glass/firebox, increased operating noise etc. Should any of these or other conditions arise, discontinue use and schedule a service check with your local licensed gas technician. The list below shows items your licensed service technician will need to check and service at least annually. Clean Inspect Check • Glass • Pilot assembly • Voltage on thermocouple/thermopile (mil- • Interior bricks / panels • Burner livolt models) • Burner ports & burner air shutter •...
  • Page 74: Parts - Main Assembly

    parts list Parts - Main Assembly 11 15 | Gi33 Direct Vent Gas Insert...
  • Page 75 parts list Parts - Main Assembly ITEM PART # DESCRIPTION ITEM PART # DESCRIPTION 391-574/P Valve Assembly - NG 911-210 External Antenna 391-576/P Valve Assembly - LP 391-026 Pressure Relief Plate Center 911-188 Valve NG 885 SIT IPI 0.885.009 391-078 Pressure Relief Gasket 911-189 Valve LP 885 SIT IPI...
  • Page 76: Faceplates/Accessories

    parts list Faceplates/Accessories ITEM PART # DESCRIPTION ITEM PART # DESCRIPTION 391-936 Backing Plate Oversized 391-940 Mantel Deflector 391-937 Backing Plate Custom 3-Sided* 391-941 Adjustable Hearth Trim 391-938 Backing Plate Custom 4-Sided* 311-934 Oak Log Set 391-124 Bracket Backing Plate 311-931 Birch Log Set 391-920...
  • Page 77 notes Gi33 Direct Vent Gas Insert |...
  • Page 78: Warranty

    warranty Limited Lifetime Warranty FPI Fireplace Products International Ltd. (for Canadian customers) and Fireplace Products U.S., Inc. (for U.S. customers) (collectively referred to herein as “FPI”) extends this Limited Lifetime Warranty to the original purchaser of this appliance provided the product remains in the original place of installation. The items covered by this limited warranty and the period of such coverage is set forth in the table below.
  • Page 79 warranty At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective prior to processing or authorizing of any claim. Failure to allow this upon request will void the warranty. All warranty claims must be submitted by the dealer servicing the claim, including a copy of the Bill of Sale (proof of purchase by you).
  • Page 80 warranty Limitations of Liability: The original purchaser’s exclusive remedy under this warranty, and FPI’s sole obligation under this warranty, express or implied, in contract or in tort, shall be limited to replacement, repair, or refund, as outlined above. IN NO EVENT WILL FPI BE LIABLE UNDER THIS WARRANTY FOR ANY INCIDENTAL OR CONSEQUENTIAL COMMERCIAL DAMAGES OR DAMAGES TO PROPERTY.
  • Page 81 warranty Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 84 Installer: Please complete the following information Dealer Name & Address: __________________________________________________________________ ______________________________________________________________________________________ Installer: ______________________________________________________________________________ Phone #: ______________________________________________________________________________ Date Installed: __________________________________________________________________________ Serial #:_______________________________________________________________________________ Printed in Canada Regency and Regency Horizon are trademarks of FPI Fireplace Products International Ltd. ® © Copyright 2023, FPI Fireplace Products International Ltd. All rights reserved.

This manual is also suitable for:

Gi33le-ngGi33le-lp

Table of Contents