LISTINGS AND CODE APPROVALS
These gas appliances have been tested in
accordance with AS4553, NZS 5262 and
have been certified by the Australian Gas
Association for installation and operation as
described in these Installation and Operating
Instructions.
Your unit should be serviced annually by
an authorised service person.
GFI300L Gas Inbuilt
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING:
Improper installation, adjustment, alteration,
service or maintenance can cause injury or
property damage. Refer to this manual. For
assistance or additional information consult
an authorised installer, service agency or
the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flam-
mable vapours and liquids in the vicinity of
this or any other appliance.
Installation and service must be performed
by an authorised installer, service agency or
the gas supplier.
919-293b
Models:
GFI300LNG-R
GFI300LLP-R
GFI300LULPG-R
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electrical
switch: do not use any phone
in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your gas
supplier, call the fire depart-
ment.
04/08/15

Advertisement

Table of Contents
loading

Summary of Contents for Regency Fireplace Products GFI300LNG-R

  • Page 1 Owners & Installation GFI300L Gas Inbuilt Models: GFI300LNG-R GFI300LLP-R GFI300LULPG-R PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY Improper installation, adjustment, alteration, What to do if you smell gas: service or maintenance can cause injury or Do not try to light any appli- property damage.
  • Page 2 REGENCY GAS FIREPLACE INBUILT FIREPLACE TO THE NEW OWNER Congratulations! You are the owner of a state-of-the-art Gas Inbuilt Fireplace by Regency Industries. The Regency Gas Fireplace Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a fireplace, at the flick of a switch. The model GFI300L of this series has been approved by Australian Gas Association for both safety and efficiency.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Operating Instructions Copy of Data Label ............4 Unit Dimensions ............5 Operating Instructions ..........25 Lighting Instructions.............25 Installation Shutdown Instructions ..........25 First Fire ..............25 For your safety...............6 Remote Control ............25 Gas pipe testing.............6 Summary Of Controls ..........25 Before you start .............6 Fan Operation..............25 Checklist ................6 Copy of Lighting Plate Instructions ......26...
  • Page 4: Copy Of Data Label

    INSTALLATION DATA BADGE NOTE: Regency units are constantly This is a copy of the label that accompanies being improved. Check the label on the unit and each Regency GFI300L Gas Inbuilt fireplace. We have printed a copy of the contents here if there is a difference, the label on the unit is the for your review.
  • Page 5: Unit Dimensions

    INSTALLATION UNIT DIMENSIONS 683 mm 908mm 100 mm 288 mm flue 236mm 362mm Regency GFI300L Gas Fireplace Inbuilt...
  • Page 6: For Your Safety

    INSTALLATION IMPORTANT: 2) Installation and repair should be done ONLY 9) Assemble and install the faceplate and trim. by an authorised person. SAVE THESE 10) Install the glass front. 3) The appliance should be inspected before INSTRUCTIONS use and at least annually by an authorised 11) Install bottom louvres and flush front.
  • Page 7: Minimum Fireplace Dimensions

    INSTALLATION MINIMUM FIREPLACE DIMENSIONS The below minimum cavity requirements are to be maintained to ensure safe and proper operation of the appliance. Ensure all construction conforms to local building codes. MASONRY INSTALLATION: The minimum fireplace dimensions for a masonry installation are shown in the diagrams below.
  • Page 8: Mantel Leg Clearances

    INSTALLATION MINIMUM CLEARANCES TO 6" 12" (152mm) (305mm) COMBUSTIBLES The minimum fireplace clearances for the Regency gas space heater are 26" shown in the following diagrams: (660mm) From Unit Sides A 464 mm 12" (305mm) Ceiling B 860 mm 20" Mantle C see Mantel Clearances (508mm)
  • Page 9: Mock Fireplace Dimensions

    INSTALLATION OPTIONAL MOCK FIREPLACE (ZERO CLEARANCE) DIMENSIONS (NO MASONRY CHIMNEY) Framing Description GFI300L Dimensions Framing Height 25-5/8” (650mm) Framing Width 31-1/2" (800mm) Framing Depth 16-1/2" (420mm) Corner Wall Depth 39-9/16" (1006mm) Corner Facing Wall Width 56" (1422mm) Gas Connection Opening Height 2"...
  • Page 10: Optional Mock Fireplace Installation

    INSTALLATION OPTIONAL MOCK FIREPLACE (ZERO CLEARANCE) INSTALLATION 3. Install left and right nailing brackets. Remove existing screws from the outside of the unit - line up bracket with holes in the unit and secure with Mock Fireplace (zero clearance) Kit Contents 2 removed screws.
  • Page 11: Framing & Finishing

    INSTALLATION FRAMING & FINISHING Frame in the enclosure for the unit with framing material. Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed. 2) The unit does not have to be completely enclosed in a chase. You must maintain clearances from the vent to combustible materials: See "Clearances"...
  • Page 12: Appliance Gas Connection

    INSTALLATION GAS CONNECTION GAS CONNECTION WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. 1) If the appliance is to be installed into an existing chimney system, thoroughly clean the masonry or factory built fireplace. 2) The gas connection is 1/2"...
  • Page 13: Draft Diverter Connection

    INSTALLATION GAS CONNECTION TEST FOR FLUE DRAFT DIVERTER SPILLAGE CONNECTION GAS CONNECTION WARNING: Only persons licensed to work with gas A " spillage" test must be made before the 1) Attach the flue to the flue collar on the detach- piping may make the necessary gas con- installed unit is left with the customer.
  • Page 14: Gas Line Installation

    INSTALLATION 845 S.I.T. VALVE GAS PIPE PRESSURE DESCRIPTION HIGH ELEVATION TESTING 1) On-Off Solenoid Valve EV1 The appliance must be isolated from the gas sup- This unit is approved for altitude 0 to 1372m. 2) On-Off Solenoid Valve EV2 ply piping system by closing its individual manual 3) Inlet Pressure Test Point shut-off valve during any pressure testing of the gas supply piping system at test pressures equal...
  • Page 15: Conversion Kit To Lp Or Ulpg

    INSTALLATION Conversion Kit from NG to LP or ULPG THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! 10. Remove 2 screws in location shown below to remove front bracket. 1.
  • Page 16 INSTALLATION Remove the modulator plastic cap (A) using needle nose pliers. 13. Reinstall new burner orifice LPG stamped #53 or ULPG burner orifice stamped #55 and tighten. Maximum pressure: Turn the unit ON to its highest input rating. Screw in the nut (B) to increase the outlet pressure and screw it out to decrease 14.
  • Page 17: Optional Enamel Panels

    INSTALLATION OPTIONAL ENAMEL PANELS 5) Slide the side panels into position and tighten the screw to secure the tab - repeat to install panel on opposite side of unit. 1) Unwrap the panels from the protective wrapping. 6) Reinstall glass door (see manual). 2) Remove the glass front if already installed (see manual).
  • Page 18: Log Set Installation

    GFI300L INSTALLATION LOG SET INSTALLATION LOG SET INSTALLATION Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation. Improper positioning of the logs may create carbon build-up and can alter the unit's performance which is not covered under warranty. *For Touch Ups: Satin Black paint is included.
  • Page 19 GFI300L INSTALLATION In position, the bark pattern on Log 3 should line up with the pattern on 5. Place Log 5 across Logs 1 and 2. The left side of the "Y" in Log 5 fi ts into Log 2. It should appear as if one log has split during burning. the notch in Log 1.
  • Page 20 GFI300L INSTALLATION 7. Place Log 7 on the left hand side of the burner, Log 7 will sit in a 9. Rest Log 9 upright against Log 2 as shown below notch on Log 6 and the bottom of Log 7 will rest on a tab located on the burner.
  • Page 21: Glass Door Installation

    INSTALLATION GLASS DOOR INSTALLATION 1. Lift glass door and slot keyhole in glass door over screw installed in unit body. 2. Once in position, slide glass door down and secure with 2 screws at the bottom of the door as shown below, and tighten the top 2 (two) screws. 3.
  • Page 22: Faceplate & Trim Installation

    INSTALLATION FACEPLATE & TRIM INSTALLATION 1. Hang trim over glass door frame and lower gently. 3. Secure Faceplate with 2 screws in locations shown below. 4. Install lower access panel, slide the 2 tabs located on the top of the ac- cess panel into position and secure with 2 screws as shown below.
  • Page 23: Primary Glass Guard Installation

    INSTALLATION PRIMARY GLASS GUARD INSTALLATION 1. Insert silicone grips into all four (4) glass retaining brackets. 2. Slide glass through brackets. OPTIONAL MESH GUARD INSTALLATION Regency GFI300L Gas Fireplace Inbuilt...
  • Page 24: Wiring

    INSTALLATION WIRING CAUTION: DISCONNECT POWER SUPPLY WARNING: Electrical Earthing Instructions Label all wires prior to TO UNIT PRIOR TO WORKING ON This appliance is equipped with a three pronged disconnection when (earthing) plug for your protection against ELECTRICAL COMPONENTS. servicing controls. shock hazard and should be plugged directly Wiring errors can cause into a properly earthed three-prong receptacle.
  • Page 25: Operating Instructions

    OPERATING INSTRUCTIONS INSTALLATION FIRST FIRE SUMMARY OF OPERATING CONTROLS INSTRUCTIONS The FIRST FIRE in your heater is part of the paint curing process. To ensure that the paint On/Off Button Before operating this appliance, proceed through is properly cured, it is recommended that you If the unit is switched off, pressing and releasing the following check list.
  • Page 26: Copy Of Lighting Plate Instructions

    OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS RESETTING THE UNIT NORMAL OPERATING SOUNDS OF FOR YOUR SAFETY READ BEFORE LIGHTING If the appliance goes to 'lockout', the system GAS APPLIANCES will have to be reset by depressing the reset This appliance must be installed in accordance button - located on the right side of the unit with local codes, if any;...
  • Page 27: Maintenance Instructions

    MAINTENANCE GENERAL VENT MAINTENANCE GLASS GASKET MAINTENANCE INSTRUCTIONS If the glass gasket requires replacement use a Conduct an inspection of the venting system semi- 1) Always turn off the gas valve before cleaning. tadpole glass gasket (Part # 936-155). annually. Recommended areas to inspect as follows: For relighting, refer to lighting instructions.
  • Page 28: Valve Tray Replacement

    MAINTENANCE VALVE TRAY REPLACEMENT 10. Remove 2 screws in location shown below to remove front bracket. 1. Unplug or disconnect the power source to the unit. 2. Shut off the gas supply and remove the gas connection from the valve. 3.
  • Page 29: Fan Maintenance

    MAINTENANCE PRESSURE SWITCH REPLACEMENT FAN MAINTENANCE 1. Follow steps 1-11 on previous page to access fan. Before you start ensure all power is turned off. 2. Disconnect fan wires and ground wire. 1. Follow steps 1-11 on previous page to access pressure switch. 2.
  • Page 30: Gas Pressure

    MAINTENANCE All maintenance must be carried out by a licensed qualified service person IT IS CRITICAL THAT THIS APPLIANCE IS EARTHED AND THAT THE ACTIVE AND NEUTRAL ARE NOT REVERSED Unit Operation Action required No gas to the pilot burner The pilot valve should open at the same time the ignition commence sparking. If there is no gas to the pilot, turn unit off.
  • Page 31: Main Assembly

    PARTS LIST MAIN ASSEMBLY Part # Description Part # Description Firebox Side-Back 904-553 #8 x 1/2 PAN HD PHILLIPS 626-522 Heat Exchanger Assembly 904-926 SCREW 10-32 x 5/8 PAN HEAD Firebox Top 904-122 RIVET 1/8 x 1/8 STEEL OPEN END Firebox Bottom 904-578 10-24 x 0.750 PAN HEAD PHILLIPS...
  • Page 32 PARTS LIST MAIN ASSEMBLY Regency GFI300L Gas Fireplace Inbuilt...
  • Page 33: Faceplate Assembly

    PARTS LIST FACEPLATE ASSEMBLY Part # Description 940-428/P Tempered Glass 948-066 Glass Standoff (ea) BURNER AND PILOT ASSEMBLY Part # Description 911-146 Pilot Assy NG 911-157 Pilot Assy LP Regency GFI300L Gas Fireplace Inbuilt...
  • Page 34 Regency shall in no event be liable for any special, indirect consequential damages of any nature whatsoever which are in excess of the original purchase price of the product. Any alteration to the unit which causes sooting or carboning that results in damage to the exterior facia is not the responsibility of Regency Fireplace Products.
  • Page 35: Warranty

    WARRANTY DISTRIBUTORS: Western Australia Eastern Australia New Zealand Fireplace Products Australia Pty Ltd. Aber Holdings Air Group Australia 1-3 Conquest Way 28-30 Division St. 17 Mainstreet Place, Te Rapa, Hallam, VIC 3803 Welshpool, WA 6106 PO Box 10095, Te Rapa, Hamilton New Zealand 08 9350 2200 03 9799 7277 64 78497585...
  • Page 36 Register your Regency warranty online ® www.regency-fire.com.au Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.

This manual is also suitable for:

Gfi300llp-rGfi300lulpg-r