LISTINGS AND CODE APPROVALS
These gas appliances have been tested in
accordance with AS4553, NZS 5262 and
have been certifi ed by the Australian Gas
Association for installation and operation as
described in these Installation and Operating
Instructions.
Your unit should be serviced annually by
an authorised service person.
GFI300L Gas Inbuilt
PLEASE KEEP THESE INSTRUCTIONS
FOR FUTURE REFERENCE
WARNING:
Improper installation, adjustment, altera-
tion, service or maintenance can cause
injury or property damage. Refer to this
manual. For assistance or additional in-
formation consult an authorised installer,
service agency or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other fl am-
mable vapours and liquids in the vicinity of
this or any other appliance.
Installation and service must be performed
by an authorised installer, service agency or
the gas supplier.
919-293
Models:
GFI300LNG-R
GFI300LLP-R
GFI300LULPG-R
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appli-
ance
Do not touch any electrical
switch: do not use any phone
in your building.
Immediately call your gas
supplier from a neighbour's
phone. Follow the gas sup-
plier's instructions.
If you cannot reach your gas
supplier, call the fi re depart-
ment.
02/26/14

Advertisement

Table of Contents
loading

Summary of Contents for Regency Fireplace Products GFI300LNG-R

  • Page 1 Owners & Installation GFI300L Gas Inbuilt Models: GFI300LNG-R GFI300LLP-R GFI300LULPG-R PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE WARNING: FOR YOUR SAFETY Improper installation, adjustment, altera- What to do if you smell gas: tion, service or maintenance can cause Do not try to light any appli- injury or property damage.
  • Page 2 REGENCY GAS FIREPLACE INBUILT FIREPLACE TO THE NEW OWNER Congratulations! You are the owner of a state-of-the-art Gas Inbuilt Fireplace by Regency Industries. The Regency Gas Fireplace Series of hand crafted appliances has been designed to provide you with all the warmth and charm of a fi replace, at the fl ick of a switch. The model GFI300L of this series has been approved by Australian Gas Association for both safety and effi...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Safety Label..............3 - Optional Mesh Guard ........... 19 Unit Dimensions ............5 Wiring Diagram ............20 Operating Instructions Installation Operating Instructions ..........21 For Your Safety ............6 Lighting Procedure ............ 21 Specifi cations .............. 5 Shutdown Procedure ..........
  • Page 4 INSTALLATION DATA BADGE NOTE: Regency units are constantly This is a copy of the label that accompanies being improved. Check the label on the unit and each Regency GFI300L Gas Inbuilt fi replace. if there is a difference, the label on the unit is the We have printed a copy of the contents here correct one.
  • Page 5: Unit Dimensions

    INSTALLATION UNIT DIMENSIONS 683 mm 908mm 100 mm 288 mm flue 236mm 362mm Regency GFI300L Gas Fireplace Inbuilt...
  • Page 6: For Your Safety

    INSTALLATION IMPORTANT: 3) The appliance should be inspected before 9) Assemble and install the faceplate and trim. SAVE THESE use and at least annually by an authorised service person. More frequent cleaning may 10) Install the glass front. INSTRUCTIONS be required due to excessive lint from carpet- ing, bedding material, etc.
  • Page 7: Minimum Fireplace Dimension

    INSTALLATION MINIMUM FIREPLACE DIMENSIONS The below minimum cavity requirements are to be maintained to ensure safe and proper operation of the appliance. Ensure all construction conforms to local building codes. MASONRY INSTALLATION: The minimum fi replace dimensions for a masonry installation are shown in the diagrams below.
  • Page 8: Clearances To Combustibles

    INSTALLATION MINIMUM 6" 12" CLEARANCES TO (152mm) (305mm) COMBUSTIBLES The minimum fi replace clearances for the Regency gas space heater are 26" shown in the following diagrams: (660mm) From Unit Sides A 464 mm 12" (305mm) Ceiling B 860 mm 20"...
  • Page 9: Framing Dimensions

    INSTALLATION MOCK FIREPLACE (ZERO CLEARANCE) DIMENSIONS (NO MASONRY CHIMNEY) Framing Description GFI300L Dimensions Framing Height 25-5/8” (650mm) Framing Width 31-1/2" (800mm) Framing Depth 16-1/2" (420mm) Corner Wall Depth 39-9/16" (1006mm) Corner Facing Wall Width 56" (1422mm) Gas Connection Opening Height 2"...
  • Page 10 INSTALLATION MOCK FIREPLACE (ZERO CLEARANCE) INSTALLATION 3. Install left and right nailing brackets. Remove existing screws from the outside of the unit - line up bracket with holes in the unit and secure with Mock Fireplace (zero clearance) Kit Contents 2 removed screws.
  • Page 11: Framing And Finishing

    INSTALLATION FRAMING & FINISHING Frame in the enclosure for the unit with framing material. Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed. 2) The unit does not have to be completely enclosed in a chase. You must maintain clearances from the vent to combustible materials: See "Clearances"...
  • Page 12: Gas Connection

    INSTALLATION GAS CONNECTION GAS CONNECTION WARNING: Only persons licensed to work with gas piping may make the necessary gas connections to this appliance. 1) If the appliance is to be installed into an existing chimney system, thoroughly clean the masonry or factory built fi replace. 2) The gas connection is 12"...
  • Page 13: Flueing

    INSTALLATION GAS CONNECTION TEST FOR FLUE DRAFT DIVERTER SPILLAGE CONNECTION GAS CONNECTION WARNING: Only persons licensed to work with A " spillage" test must be made before the 1) Attach the fl ue to the fl ue collar on the detach- gas piping may make the necessary installed unit is left with the customer.
  • Page 14: Gas Pipe Pressure Testing

    INSTALLATION 845 S.I.T. VALVE GAS PIPE PRESSURE DESCRIPTION HIGH ELEVATION TESTING 1) On-Off Solenoid Valve EV1 The appliance must be isolated from the gas sup- This unit is approved for altitude 0 to 1372m. 2) On-Off Solenoid Valve EV2 ply piping system by closing its individual manual 3) Inlet Pressure Test Point shut-off valve during any pressure testing of the gas supply piping system at test pressures equal...
  • Page 15 INSTALLATION Conversion Kit for LP to ULPG Model THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit Contains: Minimum pressure: Turn unit "ON" to it's lowest input rating by setting the burner Qty.
  • Page 16: Optional Enamel Panel

    INSTALLATION OPTIONAL ENAMEL PANELS 5) Slide the side panels into position and tighten the screw to secure the tab - repeat to install panel on opposite side of unit. 1) Unwrap the panels from the protective wrapping. 6) Reinstall glass door (see manual). 2) Remove the glass front if already installed (see manual).
  • Page 17: Log Set Installation

    INSTALLATION LOG SET INSTALLATION Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation. Improper positioning of the logs may create carbon build-up and can alter the unit's performance which is not covered under warranty. *For Touch Ups: Dark Brown Paint is included for log set.
  • Page 18 INSTALLATION In position, the bark pattern on Log 3 should line up with the pattern on Log 2. It should appear as if one log has split during burning. Log 7 in position Logs 2 & 3 - continuous bark line 6.
  • Page 19: Glass Door Installation

    INSTALLATION GLASS DOOR INSTALLATION 1. Lift glass door and slot keyhole in glass door over screw installed in unit body. Log 7 in position 8. Log 8 will cover pilot assembly, resting on pilot assembly bracket and trim of the burner tray as shown below. Log 8 covers Pilot Assembly 2.
  • Page 20: Faceplate & Trim

    INSTALLATION FACEPLATE & TRIM INSTALLATION 1. Hang trim over glass door frame and lower gently. 3. Secure Faceplate with 2 screws in locations shown below. 4. Proceed to glass or optional mesh guard installation. 2. Lift Faceplate over brackets on top of unit - hook faceplate over brackets and lower gently.
  • Page 21: Glass Guard Installation

    INSTALLATION PRIMARY GLASS GUARD INSTALLATION 1. Insert silicone grips into all four (4) glass retaining brackets. 2. Slide glass through brackets. OPTIONAL MESH GUARD INSTALLATION Regency GFI300L Gas Fireplace Inbuilt...
  • Page 22 INSTALLATION WIRING CAUTION: DISCONNECT POWER SUPPLY WARNING: Electrical Grounding Instructions Label all wires prior to TO UNIT PRIOR TO WORKING ON This appliance is equipped with a three pronged disconnection when (grounding) plug for your protection against ELECTRICAL COMPONENTS. servicing controls. shock hazard and should be plugged directly Wiring errors can cause into a properly grounded three-prong recepta-...
  • Page 23: Operating Instructions

    OPERATING INSTRUCTIONS INSTALLATION FIRST FIRE SUMMARY OF OPERATING CONTROLS INSTRUCTIONS The FIRST FIRE in your heater is part of the paint curing process. To ensure that the paint On/Off Button Before operating this appliance, proceed through is properly cured, it is recommended that you If the unit is switched off, pressing and releasing the following check list.
  • Page 24: Copy Of Lighting Plate Instructions

    OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS RESETTING THE UNIT NORMAL OPERATING SOUNDS OF FOR YOUR SAFETY READ BEFORE LIGHTING If the appliance goes to 'lockout', the system GAS APPLIANCES will have to be reset by depressing the reset button - located on the right side of the unit with local codes, if any;...
  • Page 25: Maintenance

    MAINTENANCE GENERAL VENT MAINTENANCE GLASS GASKET MAINTENANCE INSTRUCTIONS If the glass gasket requires replacement use a Conduct an inspection of the venting system 1) Always turn off the gas valve before cleaning. tadpole glass gasket (Part # 936-155). semi-annually. Recommended areas to inspect For relighting, refer to lighting instructions.
  • Page 26 MAINTENANCE VALVE TRAY REPLACEMENT 10. Remove 2 screws in location shown below to remove front bracket. 1. Unplug or disconnect the power source to the unit. 2. Shut off the gas supply and remove the gas connection from the valve. 3.
  • Page 27: Fan Maintenance

    MAINTENANCE PRESSURE SWITCH REPLACEMENT FAN MAINTENANCE 1. Follow steps 1-11 on previous page to access fan. Before you start ensure all power is turned off. 2. Disconnect fan wires and ground wire. 1. Disconnect wire leads and tubing on the switch. NOTE: It is important to label wires and hose connections to ensure the new switch is hooked up in the same manner.
  • Page 28: Warranty

    MAINTENANCE All maintenance must be carried out by a licensed qualifi ed service person IT IS CRITICAL THAT THIS APPLIANCE IS EARTHED AND THAT THE ACTIVE AND NEUTRAL ARE NOT REVERSED Unit Operation Action required No gas to the pilot burner The pilot valve should open at the same time the ignition commence sparking.
  • Page 29: Parts

    PARTS LIST MAIN ASSEMBLY Part # Description Part # Description Firebox Side-Back 904-553 #8 x 1/2 PAN HD PHILLIPS 626-522 Heat Exchanger Assembly 904-926 SCREW 10-32 x 5/8 PAN HEAD Firebox Top 904-122 RIVET 1/8 x 1/8 STEEL OPEN END Firebox Bottom 904-578 10-24 x 0.750 PAN HEAD PHILLIPS...
  • Page 30 PARTS LIST MAIN ASSEMBLY Regency GFI300L Gas Fireplace Inbuilt...
  • Page 31: Parts List

    PARTS LIST FACEPLATE ASSEMBLY BURNER AND PILOT ASSEMBLY Regency GFI300L Gas Fireplace Inbuilt...
  • Page 32 NOTES Regency GFI300L Gas Fireplace Inbuilt...
  • Page 33 NOTES Regency GFI300L Gas Fireplace Inbuilt...
  • Page 34 NOTES Regency GFI300L Gas Fireplace Inbuilt...
  • Page 35: Warranty

    WARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Qual- ity Assurance Team carefully inspects each unit thoroughly before it leaves our door. Regency Industries Ltd. is pleased to extend this limited lifetime warranty to the original purchaser of a Regency Product.
  • Page 36 ® Register your Regency warranty online www.regency-fi re.com.au Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notifi cation of new product updates. • Stay informed about the current promotions, events, and special offers on related products.

This manual is also suitable for:

Gfi300llp-rGfi300lulpg-r

Table of Contents