Valve Tray Replacement - Regency Fireplace Products Gem54-NG Owners & Installation Manual

Gem54 series gas fireplace
Table of Contents

Advertisement

Warning: Turn off the unit by way of the wall switch or remote.
Allow unit to cool at least 10 min. - prior to removing
faceplate.
1) Turn the unit off and allow it to cool down to room temperature
prior to handling.
2) Turn off the gas supply to the unit.
3) Remove the faceplate by lifting it up off the hinges on the sides of the
firebox.
4) Remove the door frame overlay by swinging out 45
and lift up and out.
Regency Gemfire™ Gas Fireplace

vAlvE TRAY REplAcEMENT

5) Remove the glass door.
6) Remove the burner tray by undoing the 2 screws in between the bot-
from the bottom
o
a) Remove the 3 screws shown below at the bottom of the glass
.
door
b) Swing the door out 45
from the bottom and lift up and out.
o
tom cover and burner on the firebox. Carefully lift the burner up and
out ensuring not to spill the glass crystals.
Aerial View of the inside of the unit shown.
MAINTENANcE
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gem54-ulpgGem54-lpg

Table of Contents