Venting Arrangements; Allowable Vertical Terminations For Gem54-Ng - Regency Fireplace Products Gem54-NG Owners & Installation Manual

Gem54 series gas fireplace
Table of Contents

Advertisement

The shaded area in the diagram shows all allowable
combinations of straight vertical and offset to vertical
terminations, using two 90
elbows, with Rigid Pipe Venting
o
Systems for Natural Gas. Two 45
elbow. Maximum of four 45
elbows allowed.
o
"This uniT musT always
TeRminaTe / venT
diRecTly To The ouTdooRs."
Please note min. 0.3m between 90
is required.
Vent must be supported at offsets.
Firestops are required at each floor level and
whenever passing through a wall.
Maintain clearances to combustibles as listed in
the "Clearances" section.
Refer to the "Vent Restrictor Position" section
for details on how to change the vent restrictor
from the factory setting of Set 1 to Set 2 or Set 3
if required.
Note: Must use optional flue adaptor when using
Rigid Pipe (Part # 770-994).
Regency Gemfire™ Gas Fireplace

vENTING ARRANGEMENTS

ALLOWABLE VERTICAL TERMINATIONS FOR GEM54-NG

elbows equal to one 90
o
o
elbows
o
2
4
0
40
38
36
34
32
30
Vent Restrictor on Set 3
28
26
24
22
Vent Restrictor on Set 2
20
18
16
14
12
10
8
6
4
2
0
Max. 10' (3m)(centerline to centerline)
Minimum length of pipe
between elbows 12" (305mm)
installation
Horizontal (Feet)
8
6
10
12
Vent Restrictor on Set 1
(factory setting)
14
18
16
20
23