Regency Fireplace Products Greenfire GF950L Owners & Installation Manual

Regency Fireplace Products Greenfire GF950L Owners & Installation Manual

Hide thumbs Also See for Greenfire GF950L:
Table of Contents

Advertisement

Quick Links

Greenfire
Gas Fireplace
www.regency-fire.com.au
WARNING:
If the information in these instructions are not followed exactly,
a fire or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use petrol or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
920-234a
GF950L
®
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Owners &
Installation Manual
MODELS: GF950LNG-2
GF950LLP-2
GF950LULPG-2
LISTINGS AND CODE APPROVALS
These gas appliances have been tested
in accordance with AS 5263.0, AS/NZS
5263.1.3 and have been certified by IAPMO
Oceana for installation and operation as
described in these Installation and Operating
Instructions.
Must be installed as per AS/NZS5601
Your unit should be serviced annually by
an authorised service person.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance.
Do not touch any electrical switch.
Do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
March 1, 2021

Advertisement

Table of Contents
loading

Summary of Contents for Regency Fireplace Products Greenfire GF950L

  • Page 1 Greenfire GF950L ® Owners & Installation Manual Gas Fireplace MODELS: GF950LNG-2 GF950LLP-2 GF950LULPG-2 LISTINGS AND CODE APPROVALS These gas appliances have been tested in accordance with AS 5263.0, AS/NZS 5263.1.3 and have been certified by IAPMO Oceana for installation and operation as described in these Installation and Operating Instructions.
  • Page 2 PAIRING YOUR REMOTE CONTROL The control box will only learn the Remote ID codes during the first 30 seconds after power is applied and will ignore this special command from the Remote after the first 30 seconds. To the New Owner: To match the control box to the remote, follow the steps below : Congratulations! 1.
  • Page 3: Table Of Contents

    table of contents Flue Arrangements for Horizontal Terminations Copy of Data Badge ............5 -Inline Horizontal Flue Chart ........39 Unit Dimensions ............6 Flue Restrictor Position ..........39 Horizontal Terminations - Inline Power Flue Installation ..............7 102mm x 168mm Flex Flue ........40 Important Message ............7 Unit Installation with Horizontal Termination 102 mm x General Safety Information ..........7 168 mm Flueing (Flex Flue Systems) ......41...
  • Page 4 table of contents Inner Panel Removal / Installation .......72 Faceplate and Deflector Installation ......73 Screen & Inner Door Frame Installation ......74 Optional Finishing Trim Installation ......75 Operating Instructions ..........76 Operating Instructions ..........76 Lighting Instructions ............76 Shutdown Instructions ..........76 First Fire ..............76 Remote Control ............76 Summary of Controls ..........76 Fan Operation ..............76...
  • Page 5: Copy Of Data Badge

    data badge This is a copy of the data badge that accompanies each GF950L Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency ® units are constantly being improved. Check the badge on the unit and if there is a difference, the badge on the unit is the correct one. COPY OF DATA BADGE Regency Gas Fireplace Model...
  • Page 6: Unit Dimensions

    DIMENSIONS dimensions UNIT DIMENSIONS 500mm 1091mm 560mm 996mm 523mm 14mm 890mm Unit shown with Black Flat Fascia 996mm 1192mm 989mm 990mm 1000mm 1034mm Unit with Finishing Trim - Flush Finish Black Premium Glass Fascia Regency GF950L-2 Gas Fireplace...
  • Page 7: Installation

    installation IMPORTANT MESSAGE 11. Under no circumstances should this appliance YOUNG CHILDREN SHOULD BE be modified. Parts that have to be removed SAVE THESE INSTRUCTIONS CAREFULLY SUPERVISED WHEN for servicing should be replaced prior to operating this appliance. THEY ARE IN THE SAME AREA AS THE APPLIANCE.
  • Page 8: Installation Checklist

    installation INSTALLATION CHECKLIST 4. The GF950L Direct Vent Gas Fireplace is This includes: approved for alcove installations, see "Clear- ances" section for details. 1) Clocking the appliance to ensure the correct IMPORTANT : Thought will need to be given firing rate (rate noted on label) after burning to determine how this will be finished.
  • Page 9: Clearances

    installation CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and flue system be installed only in accordance with these instructions. Caution Requirements WARNING The top, back and sides of the fireplace are defined by...
  • Page 10: Framing Dimensions

    installation FRAMING DIMENSIONS IMPORTANT NOTE: Framing Description GF950 This unit can be finished Dimensions with combustible facing Framing Height 940 mm combustible finish material of thickness range ¹ Framing Height -Steel Stud 756mm non combustible steel stud 10-19mm OR non-combus- Framing Width 1127 mm tible facing material of a...
  • Page 11: Combustible Finishing Unit Assembly/ Finishing/ Mantel Clearances + Mantel Leg Clearances

    installation COMBUSTIBLE FINISHING UNIT ASSEMBLY/ FINISHING/ MANTEL CLEARANCES + MANTEL LEG CLEARANCES UNIT ASSEMBLY PRIOR TO INSTALLATION The nailing strips must be correctly positioned and attached before unit is slid into position. NAILING STRIPS-COMBUSTIBLE FINISHING The nailing strips come attached to the unit. There is 1 plate on each side, 1 on the top.
  • Page 12: Framing & Finishing (Combustible)

    installation FRAMING & FINISHING (COMBUSTIBLE) Note: Finished *Finishing Trim or one of the fascias must be used with com- Material bustible finishing. 10mm to 19mm combustible finishing can be used if the 13mm slot 0mm-19mm thick- air gap around the front facing of the unit is maintained. Finishing ness using combus- material cannot be thicker than 19mm and must be flush with the tible finishing...
  • Page 13: Clearances For Combustible Finishing With Mantel

    installation CLEARANCES FOR COMBUSTIBLE FINISHING WITH MANTEL Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible finishing and mantel clearances are shown in the diagram on the right. Finishing Trim must be used with combustible finishing. Note: Maximum combustible finishing material thickness is 19mm (305mm) (152mm)
  • Page 14: Non-Combustible Flushed Finishing Unit Assembly/ Finishing/ Mantel Clearances + Mantel Leg Clearances

    installation NON COMBUSTIBLE FLUSHED FINISHING UNIT ASSEMBLY/ FINISHING/ MANTEL CLEARANCES + MANTEL LEG CLEARANCES REMOVE TOP NAILING STRIPS & STANDOFFS Remove the top nailing strip/standoff by removing 4 screws in locations shown in Diagram to the right, then lift off and recycle. Break off the 7 standoffs with a pair of pliers.
  • Page 15: Clearances For Non-Combustible Flushed Finishing With Mantel

    installation CLEARANCES FOR NON-COMBUSTIBLE FLUSHED FINISHING WITH MANTEL Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right. Note: For a flushed finish using non-combustible finishing, seven (305mm) (152mm) 13mm stand-off tabs around the fireplace opening must be broken...
  • Page 16: Flushed Finishing & Framing With Non-Combustible Material

    installation FLUSHED FINISHING & FRAMING WITH NON-COMBUSTIBLE MATERIAL Note: For flush finishing, the top nailing strip must be removed and a non- Finished * diagrams shown below are combustible steel stud support added. Material with top nailing strip removed. The seven fireplace opening standoffs which are located on this unit can be removed when non combustible material is installed flush with the unit.
  • Page 17: Installing A Tv / Artwork Flush With The Unit

    installation INSTALLING A TV / ARTWORK FLUSH WITH THE UNIT Note: All wiring should stay free and clear of the flue system to avoid damage due to heat, if located directly in front of the flue system. Ensure wiring is secured without any sag. Heat deflector must overhang front of TV by 51mm.
  • Page 18: Installing A Tv / Artwork Enclosed Above The Unit

    installation INSTALLING A TV / ARTWORK ENCLOSED ABOVE THE UNIT Maximum recess ''depth'' is 146mm. Minimum height is 370mm from top lip. " 146mm 146mm DETAIL M SCALE 1 : 6 Ensure framing does not interfere with flueing Regency GF950L-2 Gas Fireplace...
  • Page 19: Optional Framing Kit

    GF950 installation OPTIONAL FRAMING KIT OPTIONAL FRAMING KIT 1. Construct the timber framing, ensure inside dimensions are 940mm H x 1127mm W as shown below. 1127mm (468-025) 940mm Flat side out 5. Secure horizontal steel header stud (468-039) with 2 screws per side as per diagram.
  • Page 20: Non-Combustible Facing Installation

    7. Paint walls using a high quality paint which will withstand the high Discoloration is not the responsibility of Regency Fireplace Products, temperatures being emitted from this appliance. we believe careful attention to the recommendations provided here will be result in aesthetically pleasing result free of issues outlined above.
  • Page 21: Framing & Finishing (Clean Finish Installations Only)

    installation FRAMING & FINISHING (CLEAN FINISH INSTALLATIONS ONLY) 1. Frame in the enclosure for the unit with framing material. IMPORTANT: The framed opening must be of non-combustible material. Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed.
  • Page 22: Flue Restrictor Position

    installation FLUE RESTRICTOR POSITION FLUE RESTRICTOR SETTING Flue restriction is required for certain flueing installations, see the diagrams in the "Flueing Arrangements" section to determine if they are required for your installation. The Flue Restrictor plate is located on the inside top of the firebox. Set 3 - 18mm open To set the flue restriction as indicated in the flueing arrangements diagrams, refer to the following instructions;...
  • Page 23: Natural Flue

    installation NATURAL FLUE EXTERIOR FLUE TERMINATION LOCATIONS FIGURE 6.2 (in part): LOCATION OF FLUE TERMINALS OF BALANCED FLUE AS/NZ 5601, ROOM-SEALED, FAN ASSISTED OR OUTDOOR APPLIANCE Regency GF950L-2 Gas Fireplace...
  • Page 24: Clearances

    installation CLEARANCES Minimum clearances (mm) Ref. Item Natural Draught Below eaves, balconies and other projections: Appliances up to 50 MJ/h input Appliances up to 50 MJ/h input From the ground, above a balcony or other surface* From a return wall or external corner* From a gas meter (M) (see Note 5) (see Clause 5.11, 5.9 for flue terminal location of regulator) 1000...
  • Page 25: 102Mmx168Mm Rigid Pipe Cross Reference Chart

    installation 102 MM X 168 MM RIGID PIPE CROSS REFERENCE CHART 102 MM X 168 MM RIGID PIPE CROSS REFERENCE CHART Not all rigid pipe components are available directly from Regency. Not all Rigid Pipe components are available directly from FPI. Description Simpson Direct Vent Pro...
  • Page 26 installation Description Simpson Direct Vent Pro ® Attic Insulation Shield 305 mm 46DVA-IS Attic Insulation Shield - Cold Climates 914 mm 46DVA-KHA High Wind Vertical Cap 46DVA-VCH/9 Horizontal Square Termination Cap 46DVA-HC Vertical Termination Cap 46DVA-VC Storm Collar 46DVA-SC Flashing - Flat Roof 46DVA-FF Adjustable Flashing 0/12-6/12 46DVA-F6...
  • Page 27: Flueing Introduction (Non Power Flue)

    installation FLUEING INTRODUCTION (NON POWER FLUE) The GF950L uses the "balanced flue" technology Co-Axial system. The inner liner flues products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney. Note: These flue pipes must not be connected to any other appliance.
  • Page 28: Flueing Arrangements - Horizontal Termination (Flex)

    installation FLUEING ARRANGEMENTS (NON POWER FLUE) HORIZONTAL TERMINATION (FLEX) Regency Direct Vent System ® These flueing systems, in combination with GF950L, have been tested and listed as a Direct Vent system by IAPMO. The location of the termination cap must conform to the requirements in the Flue Terminal Locations diagram from the "Exterior Flue Termination Locations"...
  • Page 29: Horizontal Terminations-Rigid Pipe 102Mmx168Mm

    installation HORIZONTAL TERMINATIONS (NON POWER FLUE) RIGID PIPE 102MM X 168MM The minimum components required for a basic horizontal termination are: Horizontal Termination Cap Elbow Rigid Pipe Adaptor (510-994) Wall Thimble Length of pipe to suit wall thickness (see chart) Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap.
  • Page 30 installation HORIZONTAL TERMINATIONS (NON POWER FLUE) RIGID PIPE 102MM X 168MM The diagrams below shows examples of horizontal termination arrangements using one 90 elbow. 1) A maximum of one 90 or two 45 elbows is permitted. 2) Minimum distance between elbows is 305mm. •...
  • Page 31: Flueing Arrangement For Vertical Terminations

    installation FLUEING ARRANGEMENT FOR VERTICAL TERMINATIONS (NON POWER FLUE) Vertical Flueing with Two (2) 45 Elbows Metres The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two elbow, with Rigid Pipe Flueing Systems. •...
  • Page 32: Direct Flue Wero Clearance Top Exit Vertical Flue Kit

    installation DIRECT FLUE ZERO CLEARANCE TOP EXIT VERTICAL FLUE KIT INSTALLATION INSTRUCTIONS GF950 (NON POWER FLUE) This flue kit has been manufactured for use with GF950L and to be installed in accordance with AS/NZS 5601. To ensure safety and correct unit operation this flue kit must be installed as outlined in these instructions.
  • Page 33: Vertical Termination - Vertical Flex Flue Kit

    installation VERTICAL TERMINATION (NON POWER FLUE) 102 MM X 168 MM FLUEING - VERTICAL FLEX FLUE KIT (946-768) VERTICAL TERMINATION When using vertical flex kit (Part #946-768), if the overall length of this vertical flex kit is too short an additional 6m flex kit extension (sold separately) is available (part #946-756).
  • Page 34: Vertical Flue Extension Kit

    installation VERTICAL FLUE EXTENSION KIT (PART #946-756) VERTICAL FLUE EXTENSION KIT (PART # 946-756) 6.1 m Flex pipe Extension (Used in conjunction with the 946-768 Vertical Flex kit and 948-367/P 102 mm inner flex to flex adaptor). pipe 6 m 1.
  • Page 35: Vertical Terminations - Rigid Pipe 102Mm X 168Mm

    maintenance VERTICAL TERMINATIONS (NON POWER FLUE) RIGID PIPE 102MM X 168MM The minimum components required for a basic vertical termination using Simpson Duravent Rigid Flue System are: Vertical Termination Cap Rigid Pipe Adaptor (510-994) High wind cap Flashing Storm Collar Length of pipe to suit height requirement (see chart) Flashing...
  • Page 36: Wiring Diagram - Non Power Flue

    installation WIRING DIAGRAM - NON POWER FLUE DISCONNECT POWER SUPPLY TO UNIT PRIOR TO WORKING ON ELECTRICAL COMPONENTS. 910-936 FLAME SENSOR BLACK BLACK 910-912 911-316 BROWN BLUE GREEN BLACK WHITE 911-317 911-318 JUMPER WHITE 910-514 RESET SWITCH (NC) 911-183 OPTIONAL WIFI MODULE ON/OFF NON POWER VENT APPLICATION...
  • Page 37: Inline Power Flue

    installation INLINE POWER FLUE EXTERIOR FLUE TERMINATION LOCATIONS FIGURE 6.2 (in part): LOCATION OF FLUE TERMINALS OF BALANCED FLUE AS/NZ 5601, ROOM-SEALED, FAN ASSISTED OR OUTDOOR APPLIANCE Regency GF950L-2 Gas Fireplace...
  • Page 38: Clearances

    installation CLEARANCES Minimum clearances (mm) Ref. Item Assisted Below eaves, balconies and other projections: Appliances up to 50 MJ/h input Appliances up to 50 MJ/h input From the ground, above a balcony or other surface* From a return wall or external corner* From a gas meter (M) (see Note 5) 1000 (see Clause 5.11, 5.9 for flue terminal location of regulator)
  • Page 39: Flueing Introduction

    GF950PV Inline Power Vent Vertical or Hortizontal Installation Instructions installation FLUEING INTRODUCTION (INLINE POWER FLUE) Venting Arrangements for Horizontal Terminations The GF950L uses the "balanced flue" technology Co-Axial system. The inner liner flues products of combustion to the outside while the outer liner draws Inline Horizontal Vent Chart outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.
  • Page 40: Horizontal Terminations - Inline Power Flue 102Mm X 168Mm Flex Flue

    installation HORIZONTAL TERMINATIONS - INLINE POWER FLUE 102MM X 168MM FLEX FLUE These flueing systems, in combination with the GF950L-2 Direct Vent Gas Fireplace, have been tested and listed as a direct vent heater system. The location of the termination cap must conform to the requirements in the Flue Terminal Locations diagram in "Exterior Flue Termination Locations" section. Regency Direct Vent (Flex) System Termination Kits include all the parts needed to install the GF950L-2 using a flexible flue.
  • Page 41: Unit Installation With Horizontal Termination 102 Mm

    installation UNIT INSTALLATION ASTROCAP 5) Slip the assembled liner and termination assembly through the thimble making sure the WITH HORIZONTAL TERMINATION DIMENSIONS (946-523/P) termination cap faces up (there are markings 102MM X 168MM on the cap indicating which way is up). This will (INLINE POWER FLUE) position the termination cap with proper down (Flex Flue Systems)
  • Page 42: Horizontal Terminations - Inline Power Flue

    GF950PV Inline Power Vent Vertical or Horizontal Installation Instructions CV72EPV / CB72EPV installation Inline Power Vent Vertical or Hortizontal Installation Instructions HORIZONTAL TERMINATIONS - INLINE POWER FLUE Horizontal Terminations - Inline Power Flue RIGID PIPE 102MM X 168MM -5/8" (102mm x 168mm) Rigid Pipe 4"...
  • Page 43: Unit Installation With Horizontal Termination 102 Mm X 168 Mm Flueing (Rigid Flue Systems)

    installation UNIT INSTALLATION 5) Assemble the desired combination of pipe and 7) Ensure that the pipe clearances to combustible elbows to the appliance flue outlets and secure. materials are maintained (Diagram 2). Install the WITH HORIZONTAL TERMINATION termination cap. (INLINE POWER FLUE) 102MM X 168MM FLUEING Note: If installing termination on a siding Note: For best results and optimum...
  • Page 44: Flueing Arrangement For Vertical Terminations - Inline Power Flue

    GF950PV Inline Power Vent Vertical or Hortizontal Installation Instructions installation FLUEING ARRANGEMENT FOR VERTICAL TERMINATIONS - INLINE POWER FLUE Venting Arrangement for Vertical Terminations-Inline Power Vent Vertical flueing with straight vertical flueing and or with a max. of six (6) 90 Elbows (1 - 90 2 - 45 Vertical flueing with straight vertical flueing and or with a max.
  • Page 45 installation Termination Cap Storm Collar VERTICAL INLINE POWER FLUE TERMINATIONS Flashing FLEX PIPE (VERTICAL FLEX KIT PART #946-755) When using vertical flex kit (Part #946-755), if the overall length of this vertical flex kit is too short an additional 6m flex kit extension (sold separately) is available (part #946-756).
  • Page 46: Vertical Inline Power Flue Terminations Flex Pipe

    installation VERTICAL INLINE POWER FLUE TERMINATIONS FLEX PIPE 19. Slide the finished length up towards the flashing ensuring the length of pipe is a minimum of 609 mm measured from the top of the roof. Level the chimney and secure using the roof support provided with kit to bottom side of the roof as shown using a minimum of 2 screws per side- see Diagram 3b.
  • Page 47: Ceiling Firestop/Firestop Spacer

    installation VERTICAL FLUE EXTENSION KIT (APPROVED MODELS) VERTICAL FLUE EXTENSION KIT HORIZONTAL POWER VENT KIT (CV72EPV, CB72EPV, CB40EPV, CV40EPV, & CC40EPV ONLY) HORIZONTAL POWER FLUE KIT (PART # 946-756) (PART # 946-756) 6m Flex Pipe Extension Used in conjunction with the 946-765 Inline power flue where a 102mm inner pipe maximum of 2 946-756 may be used up to a maximum of 12 meters.
  • Page 48: Vertical Inline Power Flue Terminations Rigid Pipe

    GF950PV Inline Power Vent Vertical or Horizontal Installation Instructions installation Vertical Inline Power Vent Terminations VERTICAL INLINE POWER FLUE TERMINATIONS RIGID PIPE Rigid Pipe High Wind Cap The minimum components required when using inline power Storm Collar flue are: High Wind Cap Flashing Rigid Pipe Adaptor (not supplied)
  • Page 49 installation VERTICAL INLINE POWER FLUE TERMINATIONS RIGID PIPE 102MM X 168MM 4) Assemble the desired pipes and elbows. Ensure Note: A top clearance of 76mm and side bottom all pipes and elbow connections are twist-locked clearance of 51mm must be maintained, Flue and sealed.
  • Page 50: Bypass Adjustment

    GF950PV installation Bypass Adjustment BYPASS ADJUSTMENT (INLINE POWER FLUE) IMPORTANT: Adjust the bypass plate before installing the inline power flue. Refer to the flueing section for your unit’s bypass setting. Once the inline power flue is installed and the flueing is connected, the bottom access panel to the bypass plate may not be accessible for further adjustment. A bypass plate is used to adjust the flowrate of the exhaust being pulled from the unit.
  • Page 51: Inline Power Flue Dimensions

    installation INLINE POWER FLUE DIMENSIONS 433mm 362mm 396mm 312mm 114mm 297mm 111mm 82mm 113mm 148mm 163mm Regency GF950L-2 Gas Fireplace...
  • Page 52: Gas Power Flue Installation - Framing Inline Power Flue Terminations

    CV72EPV / CB72EPV Inline Power Vent Vertical or Hortizontal Installation Instructions installation GAS POWER FLUE INSTALLATION - FRAMING Gas Power Flue Installation - Framing INLINE POWER FLUE TERMINATIONS Inline Power Flue Terminations • The inline power flue can be mounted directly onto a wall, ceiling, stud or truss. Additional supports can be built to support the power flue if needed.
  • Page 53: Power Flue Terminal Installation - Inline Power Flue Terminations

    CV72EPV / CB72EPV Inline Power Vent Vertical or Hortizontal Installation Instructions installation POWER FLUE TERMINAL INSTALLATION - INLINE POWER FLUE TERMINATIONS Power Vent Terminal Installation IMPORTANT: Pressure switch must always be oriented vertically inside the inline power vent. flue. IMPORTANT: The longer silicone tube is connected to the pressure switch side labelled "P" and the shorter silicone tube is connected to the side labelled "V".
  • Page 54: Gas Power Flue Installation Clearance Requirements Inline Power Flue Terminations

    CV72EPV / CB72EPV Inline Power Vent Vertical or Hortizontal Installation Instructions installation GAS POWER FLUE INSTALLATION CLEARANCE REQUIREMENTS Gas Power Flue Installation Clearance Requirements INLINE POWER FLUE TERMINATIONS Inline Power Flue Terminations Confined spaces (chase, closet, attic, behind a wall): •...
  • Page 55: Natural Flue To Power Flue Conversion

    GF950 ECS V Natural Vent to Power Vent Conversion installation NATURAL FLUE TO POWER FLUE CONVERSION Natural Flue to Power Flue Conversion WARNING ELECTRICAL CONNECTIONS SHOULD ONLY BE CARRIED OUT BY A QUALIFIED AND LICENSED ELECTRICIAN WARNING 4. Insert the power flue wire harness through the square opening. This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and require-...
  • Page 56 GF950 ECS V Natural Vent to Power Vent Conversion installation 8. Pull the ECS V module out, remove the jumper connector and discard. Connect the new power flue wiring harness as shown below to the same location of where jumper wire was located. Refer to the wiring diagram. New Wiring Harness Jumper Connector 9.
  • Page 57: Wiring Diagram - Power Flue

    installation WIRING DIAGRAM - POWER FLUE (DO NOT CUT THE GROUND TERMINAL OFF UNDER ANY CIRCUMSTANCE.) DISCONNECT POWER SUPPLY TO UNIT PRIOR TO WORKING ON ELECTRICAL COMPONENTS. CAUTION: ENSURE THAT THE WIRES DO NOT TOUCH ANY HOT SURFACES AND ARE AWAY FROM SHARP EDGES. POWER VENT CAP 911-112 PRESS.
  • Page 58: End Of Line Power Flue

    installation END OF LINE POWER FLUE EXTERIOR FLUE TERMINATION LOCATIONS FIGURE 6.2 (in part): LOCATION OF FLUE TERMINALS OF BALANCED FLUE AS/NZ 5601, ROOM-SEALED, FAN ASSISTED OR OUTDOOR APPLIANCE Regency GF950L-2 Gas Fireplace...
  • Page 59: Clearances

    installation CLEARANCES Minimum clearances (mm) Ref. Item Assisted Below eaves, balconies and other projections: Appliances up to 50 MJ/h input Appliances up to 50 MJ/h input From the ground, above a balcony or other surface* From a return wall or external corner* From a gas meter (M) (see Note 5) (see Clause 5.11, 5.9 for flue terminal location of regulator) 1000...
  • Page 60: Flueing Introduction

    installation FLUEING INTRODUCTION (END OF LINE POWER FLUE) The GF950L uses the "balanced flue" technology Co-Axial system. The inner liner flues products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney. Note: These flue pipes must not be connected to any other appliance.
  • Page 61: Unit Installation With Horizontal Terminations - End Of Line Power Flue 102 Mm X 168 Mm Flex Flueing

    installation UNIT INSTALLATION NOTE: Horizontal sections must be supported at intervals not exceeding 3 feet (0.9 WITH HORIZONTAL TERMINATION- meter). (Flame picture and performance END OF LINE POWER FLUE will be affected by sags in the liner). 102MM X 168MM FLEX FLUEING 4.
  • Page 62: Horizontal Terminations - End Of Line Power Flue Rigid Pipe 102Mm X 168Mm

    installation HORIZONTAL TERMINATIONS - END OF LINE POWER FLUE RIGID PIPE 102MM X 168MM The minimum components required for a basic horizontal termination are: Power Flue Kit Rigid Pipe Adaptor Length of pipe to suit wall thickness and total flue run (see Table 1) Power Flue Kit (Part # 946-542)
  • Page 63: Unit Installation With Horizontal Terminations - End Of Line Power Flue 102 Mm X 168 Mm Rigid Flueing

    installation UNIT INSTALLATION WITH HORI- 5. Assemble the desired combination of pipe and elbows to the appliance adaptor and twist-lock ZONTAL TERMINATION for a solid connection. END OF LINE POWER FLUE 102MM X 168MM RIGID FLUEING Note: For best results and optimum performance with each approved flueing system, it is a minimum to Minimum Flue Clearances...
  • Page 64: End Of Line Power Flue

    installation GAS POWER FLUE INSTALLATION - END OF LINE POWER FLUE 5. Install Power Flue unit into framed opening using 4 screws as shown below. WARNING ELECTRICAL CONNECTIONS SHOULD ONLY BE CARRIED OUT BY A QUALIFIED AND LICENSED ELEC- TRICIAN 1.
  • Page 65: System Data

    installation PILOT ADJUSTMENT NOTE: The outlet pressure must be set to maximum GF950L-NG SYSTEM DATA 2.49 kPa for both Propane/ULPG and 0.87 kPa for NG. Min. Supply Pressure 1.13 kpa Periodically check the pilot flames. Correct flame pattern has two strong blue flames: 1 flowing Minimum pressure: Remove one of the cables con- Low Setting Man.
  • Page 66: I.t. Valve Description

    installation 845 S.I.T. VALVE DESCRIPTION 1) On-Off Solenoid Valve EV1 2) On-Off Solenoid Valve EV2 3) Inlet Pressure Test Point 4) Outlet Pressure Test Point 5) Connection for Pressure Regulator/Combustion Chamber Compensation 6) Pressure Regulator for Minimum and Maximum Outlet Pressure 7) Gas Outlet Pressure Electric Modulator 8) Pilot Outlet 9) Main Gas Outlet...
  • Page 67: Optional Fan Ducting Kit Installation

    installation GF950 OPTIONAL FAN DUCTING KIT INSTALLATION OPTIONAL FAN DUCTING KIT INSTALLATION LISTINGS AND CODE GENERAL INFORMATION Maximum Duct Run: 9.0m Kit Contains 4.5m APPROVALS The Fan Kit increases the eff ectiveness of your fi replace by dispersing warm air from the fi replace If you require more than 4.5m please purchase Fan This Fan Kit has been approved for use with GF950.
  • Page 68: Optional Fan Kit Installation

    installation GF950 OPTIONAL FAN KIT INSTALLATION OPTIONAL FAN KIT INSTALLATION NOTE: Installation of Fan Kit should be done prior Air Duct to installation of the wall. 2. Mount and secure the fan housing assembly to framing members, the front of the fan housing will protrude 12.7mm out of the wall so it may be fi...
  • Page 69: Fan Duct Extension Kit Installation

    GF950 installation OPTIONAL FAN KIT INSTALLATION FAN DUCT EXTENSION KIT INSTALLATION FAN DUCT EXTENSION KIT In order to use the fan extension duct kit, you must have fan kit. This kit allows you to extend the fan duct to 9m. 1.
  • Page 70: Log Set Installation

    gF900 installation LOG SET INSTALLATION Log Set InStaLLatIon Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation. Improper positioning of the logs may create carbon build-up and can alter the unit's performance which is not covered under warranty.
  • Page 71 GF900 installation 7. Position Log 6 to rest on Log 1 and Log 3 as shown in Diagram 9. 4. Rest Log 4 on Log 1 and Ceramic Log Burner as shown in Diagram 6. Diagram 9 Diagram 6 8. Line up locator on bottom of Log 7 with locator on Ceramic Log Burner as shown in Diagram 10.
  • Page 72: Front Trim Removal / Installation

    installation FRONT TRIM REMOVAL / INSTALLATION 1. Remove faceplate, inner door frame, and glass door if already installed - see instructions in this manual. 2. Remove two (2) screws in locations shown below to remove front trim piece. 3. Reverse steps to reinstall. Front Trim Piece Diagram 1 - Front Trim Screw Locations INNER PANEL REMOVAL / INSTALLATION...
  • Page 73: Faceplate And Deflector Installation

    GF900 installation FACEPLATE AND DEFLECTOR INSTALLATION FACEPLATE AND DEFLECTOR INSTALLATION 4 screws 1. Install the fascia to the unit by hooking the left and right side mounting brackets into the mounting slots at the side ofthe firebox as shown below. Diagram 4 3 Mounting Slots Diagram 1...
  • Page 74: Screen & Inner Door Frame Installation

    GF900 installation SCREEN & INNER DOOR FRAME INSTALLATION SCREEN & INNER DOOR FRAME INSTALLATION 1. Hang Screen Mesh over Inner Door Frame as shown in Diagram 1. 3. Install Screen and Inner Door Frame to unit over glass door frame as shown in Diagram 3.
  • Page 75: Screen & Inner Door Frame Installation

    GF900 installation GLASS SURROUND INSTALLATION Install the fascia to the unit by hooking the left and right side mounting brackets into the mounting slots at the side of the fi rebox as shown below. It is recommended that you use the fi rst mounting slot (the one closest to the door frame overlay) out of the 3 so that the faceplate and door frame overlay are fl...
  • Page 76: Operating Instructions

    operating instructions OPERATING SUMMARY OF INSTRUCTIONS CONTROLS FIRST FIRE Before operating this appliance, proceed through On/Off Button The FIRST FIRE in your heater is part of the the following check list. If the unit is switched off, pressing and releasing paint curing process.
  • Page 77: Copy Of Lighting Plate Instructions

    operating instructions COPY OF LIGHTING PLATE INSTRUCTIONS RESETTING THE UNIT NORMAL OPERATING SOUNDS FOR YOUR SAFETY READ BEFORE LIGHTING OF GAS APPLIANCES If the appliance goes to 'lockout', the system will have SUITABLE ONLY FOR INDOOR INSTALLATION to be reset by depressing the reset button - located It is possible that you will hear some sounds from This appliance must be installed in accordance on the right side of the unit by outer door frame.
  • Page 78: Maintenance

    maintenance FAN SERVICE PRIOR TO SERVICING THE FAN, ENSURE UNIT HAS COOLED TO 6. Remove access panel by removing eight (8) screws in locations ROOM TEMPERATURE, ALL POWER IS DISCONNECTED AND GAS shown in Diagram 4. SUPPLY IS TURNED OFF. 1.
  • Page 79: Maintenance Instructions

    maintenance MAINTENANCE INSTRUCTIONS GENERAL FLUE GLASS GASKET MAINTENANCE If the glass gasket requires replacement use a 1. Always turn off the gas valve before cleaning. tadpole glass gasket (Part # 936-157). Conduct an inspection of the flueing system For relighting, refer to lighting instructions. semi-annually.
  • Page 80: Troubleshooting

    maintenance Troubleshooting Guide________________ TROUBLESHOOTING ALL WORK MUST BE CARRIED OUT BY A LICENSED/QUALIFIED TECHNICIAN It is critical that this appliance is earthed and that Active and Neutral are not crossed *Pilot light models only SYMPTOM CAUSE SOLUTION Unit does not operate No power supply (240V) to unit or Check 240V power supply (No ignition &...
  • Page 81: Glass Door Installation

    maintenance GLASS DOOR INSTALLATION WARNING: Do not operate the appliance with the glass panels removed, cracked or broken. Replacement of the glass panels should be done by a licensed or qualified service person. Glass should be cool if cleaning is necessary. 1.
  • Page 82: Valve Tray Replacement

    maintenance VALVE TRAY REPLACEMENT 6. Remove burner by removing 14 screws in locations shown below. PRIOR TO VALVE TRAY REPLACEMENT, ENSURE UNIT HAS COOLED TO ROOM TEMPERATURE, ALL POWER IS DISCONNECTED AND GAS SUPPLY IS TURNED OFF. 1. Remove faceplate, inner frame, glass door, front trim piece and inner panels - see instructions in this manual.
  • Page 83: End Of Line Power Flue Maintenance External Power Flue Access

    maintenance END OF LINE POWER FLUE MAINTENANCE EXTERNAL POWER FLUE ACCESS 1. Remove 4 screws located around inner trim (Diagram 1). Replacing the power flue motor: 1. Turn off power supply. 2. Loosen 6 x 1/4” hex screws slightly. 3. Turn power flue motor counter clockwise and lift out (Diagram 7). Diagram 1 2.
  • Page 84: End Of Line Power Flue Maintenance Internal Power Flue Access

    maintenance Replacing the capacitor: END OF LINE POWER FLUE MAINTENANCE INTERNAL POWER FLUE ACCESS 1. Turn off power supply. 2. Loosen the following screws on the terminal block Note: May only be accessed if an access panel was installed for servicing from inside. and pull capacitor out.
  • Page 85: Power Flue Maintenance - External Power Flue Access Inline Power Flue

    maintenance POWER FLUE MAINTENANCE - EXTERNAL POWER FLUE ACCESS INLINE POWER FLUE 4. Disconnect the power to the motor by disconnecting the white and white 1. Remove 4 screws from the cover plate. from the terminal block. The power flue motor is now free. Diagram 1 2.
  • Page 86: Gas Appliance Maintenance

    maintenance Gas Maintenance GAS APPLIANCE MAINTENANCE Recommended Annual Routine Maintenance for Gas Fireplaces, Stoves and Inserts In order for your Regency appliance to continue to provide comfort to your home periodic maintenance must be performed to ensure it is operating at peak efficiency. The items in the list should be checked by a licensed gas service technician during the annual service check. Your unit may require more frequent maintenance checks if you notice any changes in how it operates. Operational changes to look for can include, but are not limited to, extended start up time, increased fan noise, residue/carbon build up, white build up on the glass/firebox, increased operating noise etc. Should any of these or other conditions arise, discontinue use and schedule a service check with your local licensed gas technician. The list below shows items your licensed service technician will need to check and service at least annually. Clean Inspect Check • Glass • Pilot assembly • Voltage on thermocouple/thermopile (mil- • Interior bricks / panels • Burner livolt models) • Burner ports & burner air shutter • Pressure relief gaskets/doors •...
  • Page 87: Parts List

    PARTS LIST parts list MAIN ASSEMBLY W840470 Pilot Assembly Gasket 911-113 Switch On/Off W/CAT 5 Cable 3 FT (105C) 911-112 Pressure Switch MPL-9370-0.20-DEACT 910-912 Wire Harness - From Module To Valve 911-121 Module SIT 230V (DV) 0.579.204 910-896 High Temperature Wire To Power Cord 466-014 Glass Door Frame Only 910-514...
  • Page 88 parts list PARTS LIST MAIN ASSEMBLY Regency GF950L-2 Gas Fireplace...
  • Page 89: Accessories

    parts list PARTS LIST ACCESSORIES Part # Description 32 467-922 Inner door frame - Black w/ Screen 467-932 Inner door frame - Stainless w/ Screen 467-926 Inner door frame Gloss Black w/Screen 33 467-544 Door Frame Overlay - Black 34 468-934 Fascia and Door Frame Black w/Screen 468-936 Fascia and Door Frame Stainless Steel w/Screen...
  • Page 90: Electronic Components Parts List

    parts list PARTS LIST ELECTRONIC COMPONENTS PARTS LIST Note: Depending on the model, the diagram below may not be exactly as shown - for reference purposes only. 910-936 910-082 911-258 NG 911-259 LP 910-089 910-088 910-912 910-084 910-101 910-526 910-080 911-307 911-183 910-514...
  • Page 91: Power Flue - End Of Line

    parts list PARTS LIST POWER FLUE - END OF LINE (PART # 946-542) Part Number Description 911-112/P Pressure Switch/Sensor (includes Bracket) 911-332/P Power Flue Fan Assembly 904-687 Connector Straight 946-536 Power Flue SS Front Faceplate 946-130 Power Flue SS Outer Perimeter Trim 946-157 Power Flue SS Water Deflector 911-047...
  • Page 92: Power Flue - Inline

    parts list PARTS LIST POWER FLUE - INLINE (PART # 946-765) Part Number Description 911-293/P 240 Volt Fan Motor Intake Cover Side Intake Cover Entry 904-687 Connector Clamp 666-152 Top Cover 911-112 Vacuum Switch 666-541 Outer Flue Collar Assembly 936-194 Starter Collar Gasket 923R Simpson Duravent Collar...
  • Page 93 NOTES notes Regency GF950L-2 Gas Fireplace...
  • Page 94: Warranty

    WARRANTY warranty Limited Lifetime Warranty FPI Fireplace Products International Ltd. (“the manufacturer”) through its wholly owned subsidiary, Fireplace Products Australia Pty Ltd (for Australia and New Zealand customers) and sold under the Regency® brand of fireplace products (collectively referred to herein as “FPA”), extends this Limited Lifetime Warranty to the original purchaser of this appliance provided the product remains in the original place of installation.
  • Page 95 WARRANTY warranty part is returned to the distributor, dealer or agent for inspection if requested by FPA. Alternatively, FPA may at its own discretion fully discharge all of its obligations under the warranty by refunding the verified purchase price of the product to the original purchaser.
  • Page 96 WARRANTY warranty FPA has no obligation to enhance or modify any unit once manufactured (i.e. as products evolve, field modifications or upgrades will not be performed on existing appliances). Any unit showing signs of neglect or misuse will not be covered under the terms of this warranty policy and may void this warranty.
  • Page 97 WARRANTY warranty Limitations of Liability: 1. Exclusion of implied terms The customer may have the benefit of consumer guarantees under the Australian Consumer Law. To the maximum extent permitted by law, all terms, conditions or warranties that would be implied into this Warranty or in connection with the supply of any goods or services by the supplier under law or statute or custom or international conventions are excluded.
  • Page 98 WARRANTY warranty How to Obtain Warranty Service: Customers should contact the authorised selling dealer to obtain warranty service. In the event the authorised selling dealer is unable to provide warranty service, please contact FPA by mail at the address listed below. Please include your name, address, purchase date, selling dealer, serial #, type of unit, a brief description of the problem, email and telephone contact information, and a copy of your original tax invoice.
  • Page 99 WARRANTY warranty Product Registration and Customer Support: Thank you for choosing a Regency Fireplace. Regency strives to be a world leader in the design, manufacture, and marketing of hearth products. To provide the best support for your product, we request that you complete a product registration form found on our Web Site under Customer Care within ninety (90) days of purchase.
  • Page 101 NOTES notes Regency GF950L-2 Gas Fireplace...
  • Page 102 notes NOTES Regency GF950L-2 Gas Fireplace...
  • Page 104 IMPORTANT: A certificate of compliance or equivalent by an authorised installer must be obtained on commissioning of appliance to obtain warranty. Regency and Greenfire are registered trademarks of FPI Fireplace Products International Ltd. © Copyright 2021, FPI Fireplace Products International Ltd. All rights reserved.

Table of Contents