System Status Messages

Zone Number / Zone Name
In alarm – This zone has triggered a system alarm condition
Is bypassed – This zone is isolated (disabled) and will not activate an alarm
Chime is set – This zone is part of the chime group
Is not secure – This zone is not closed
Fire alarm – This zone has triggered a fire alarm
Tamper – This zone has triggered a tamper alarm
Trouble fault – This zone has an open circuit
Loss of wireless supervision – This zone is a wireless device and has lost its communication link
with the control panel
Low battery – This zone is a wireless device and needs its battery changed
Partition Number / Partition Name
Is on in the away mode – This partition is armed in the away mode
Is on in the stay mode – This partition is armed in the stay mode
Is ready – This partition is secure and ready to be armed
Is not ready – This partition is NOT ready to be armed, a zone is not secure
All partitions are on in the away mode – All partitions in this multi partition system are armed in
the away mode
All partitions are on in the stay mode – All partitions in this multi partition system are armed in the
stay mode
All partitions are ready – All partitions in this multi partition system are secure and ready to be
armed
System
AC power fail – The security system has lost its electricity power
Low battery – The security systems back up battery requires charging
Battery test fail – The security systems back up battery requires changing
Box tamper – The security systems cabinet tamper input has activated
Siren trouble – The security systems external siren has a problem
Over current – The security system is drawing too much current
Time and date loss The security system time and date need resetting
Communication fault – The security system has detected a problem with the phone line
Expander
Low battery – A remote power supply's back up battery requires charging
AC power fail – A remote power supply has lost its electricity power
Box tamper – An expanders cabinet tamper input has activated