Interlogix NX-595E Installation Manual page 39

Hide thumbs Also See for NX-595E:
Table of Contents

Advertisement

Location 2 - Number of Rings
Location 2 contains the number of rings the NX-595E must detect before
answering the telephone line when initiating a communication session. A
value of 1 – 15 can be entered in this segment. Generally rings to answer
would be disabled when enabling answering machine defeat.
Segment 1
Location 3 - Dial Attempts
Location 3 is used to enter the number of dial attempts the NX-595E will make
before ending the communication cycle. A value from 1 – 15 may be used,
and the default is 6.
Segment 1
6
Location 4 - Voice Reporting Features
Event Selection for all Voice dialing numbers
Segment 1
(1)
Alarms
(2)
Alarm Restores
(3)
Open / Close (alarm system disarmed = Open, alarm system armed = close.
(4)
Zone Bypass and restores
(5)
Zone Trouble and restores
(6)
Power Trouble and restores (AC Failure or Low Battery)
(7)
Tamper and restores (Zones, Box, Keypad and Zone Activity Monitor)
(8)
Test Reports
Segment 2
(1)
System Trouble and restores (Siren, Phone, Expander, Short Circuit)
(2)
Failure to Communicate
(3)
Sensor Lost or Sensor Low Battery
(4)
Program mode, Download and Log Full (full log must be enabled in system
options)
(5)
Cancel Code (cancel reporting must be enabled in partition options)
(6)
Recent Closing, Exit Error
(7)
Reserved
(8)
Reserved
NX-595E Installation Manual