Wiring The NX-595E

Remove all power to the NetworX security system and connect NX-595E's
terminals POS, COM & DATA to the NetworX bus.
A 5-wire interconnecting cable is supplied with the NX-595E. Connect one end to
J1 (Audio Tap) on the NX-595E and the other end to J4 (Audio Tap) on the
NetworX board.
Important: Ensure the trace is aligned with pin 1 on both taps. Refer to
Figure 4, 5, 6 & 7 for correct orientation.
1. Connect J14 (RJ45) to available network port via a patch cable.
2. Connect E1C, E1A, E1+ in parallel to front door camera 1
3. Connect E2C, E2A, E2+ in parallel to front door camera 2
4. Connect V1+, V1- and V2+, V2 audio input in parallel with NX-181xx audio
lines A and B
5. Connect Zones as required:
3.3K Single EOL's
3.7K Lower zone EOL's (when zone doubled)
6.9K Higher zone EOL's (when zone doubled)
6. Select relay contact requirements via jumpers J10 and J11. Place link
between GND and C for negative switch, and 12 V+ and C for positive switch,
remove link for dry contact switching.
When integrating the NX-595E with an external camera and video monitor, it is
important to power up the monitor before you power up the NX-595E. The NX-
595E will then identify the presence of the monitor, and switch off its 5 VDC
supplied to E1A and E2A and utilize the power supplied from the video monitor.
NetworX / NX Audio tap connections
Figure 4
NX8
NX-6
Terminal Strip
NX-4
Figure 5
Terminal Strip
12
NX-4, 6, 8
NX-8E
NX-595E Installation Manual