Aiphone IX-MV Setting Manual page 255

Ip network-compatible intercom
Hide thumbs Also See for IX-MV:
Table of Contents

Advertisement

 Call Timeout [sec] ♦♠
Description
Settings
Default values
 Ringback Tone Count [time(s)] ♠ (Door Station only)
Description
Settings
Default values
6.2.4. Master Station Call Group Assignment (Master Station only)
 Group Number
Description
Settings
Default values
 Priority
Description
Settings
Default values
System Settings (Settings (Station View))
Set the call ring timer for a contact input call.
• 10-600 sec (by 1 sec)
• Infinite: Ringing continues until the caller stops or the recipient responds.
10-600 sec, 60 sec
Set the count of ringback tone.
• Infinite: Ringing continues until the recipient responds
• 1-20 times
Infinite
Set the group number of the group to be called when a contact input is triggered on the
Master Station.
Enter the group number directly, or click
group in "6.2.5. Master Station Group List (Master Station only)"
01-99
-
Set the priority of the call when a contact input is triggered on the Master Station.
• Normal
• Priority
• Urgent
Normal