Aiphone IS Series Quick Start Programming Manual

Aiphone IS Series Quick Start Programming Manual

Standard (ip) system; connecting is local with is network based equipment
Hide thumbs Also See for IS Series:

Advertisement

Quick Links

Quick Start Programming Guide
Setting Manual / Operation Manual / Installation Manual)
IS SERIES
Standard (IP) System
Connecting IS Local with IS Network Based Equipment
IS-IPC
1
2
3
ABC
DEF
PRIVACY
TRANSFER
LIST
4
5
6
GHI
JKL
MNO
7
8
9
PQRS
TUV
WXYZ
ZOOM
WIDE
0
#
IS-MV
ATTENTION:
A
This is an abbreviated programming manual, addressing basic program settings for an
T
IS Series Hybrid (Local + IP) System. A complete set of instructions
All the ports except [LAN] are not for LAN network.
Do NOT connect to LAN network.
TELEPHONE
IS-CCU
CO
IS-RCU
1P1
1P2
IS-IPC
SETTING
can be found on the CD provided with the IS-IPC.
STRIP LENGTH
11m
POWER
φ0.8~φ1.2
00-MA-CA-DD-RE-SS
ETHERNET
DC48 V
LAN
1P3
Link/
ACT
STATUS
IS-DV
(Standard (IP) System

Advertisement

Table of Contents
loading

Summary of Contents for Aiphone IS Series

  • Page 1 IS-MV ATTENTION: This is an abbreviated programming manual, addressing basic program settings for an IS Series Hybrid (Local + IP) System. A complete set of instructions (Standard (IP) System can be found on the CD provided with the IS-IPC. Setting Manual / Operation Manual / Installation Manual)
  • Page 2: General Precautions

    This guide is intended to be used for a single site IS Hybrid system running on a IPV4 network that includes an IS-IPC control unit, IS-IP door stations, IS-IPMV master stations, and IS-SOFT PC master stations. Note: Refer to the IS SERIES Standard (IP) System SETTING MANUAL when using a IPV6 network or when multiple sites are required.
  • Page 3: Network Connections

    B. A security certifi cate error message will appear. Click “Continue to this website.” C. Choose preferred language. D. Log in to the unit using the default administrator ID “aiphone,” and default password “aiphone”. E. Click the Standard system (IP system) radio button.
  • Page 4 B. A security certifi cate error message will appear. Click “Continue to this website.” C. Choose preferred language (see Figure 5.1). D. Log in to the unit using the default administrator ID “aiphone,” and default password “aiphone” (see Figure 5.2). Figure 5.1: Select Language Figure 5.2: ID and Password...
  • Page 5 C. Enter the Host unit IP address (This will be the Static IP address assigned to the host unit in Step 7). D. By default DHCP is utilized. Aiphone recommends assigning a static IP address by clicking the Static IP Address radio button and entering a unique IP address and Subnet Mask. (see Figure 6.1) E.
  • Page 6 Each IS-IPC can connect to a single IS-RCU or an IS-CCU with up to 2 IS-SCU and 4 IS-RCU control units. C. Click Temporarily stored to save changes. Figure 9.1: Control Units Composition 6 | IS Series Hybrid System Programming Guide...
  • Page 7: Step 10: Registering Stations

    Step 10: Registering Stations A. Select Registering stations from the menu on left. B. The Registering stations table will be populated based on the settings made in Steps 8 & 9. Enter a Station number and Station name for each door/master unit (see Figure 10.1). C.
  • Page 8: Step 12: Time And Date Setting

    Register Products (Recommended from Aiphone Corporation in the U.S.A.) We recommend that the IS hardware and IS-SOFT be registered. This will enable Aiphone Corporation to send alerts to the end user of fi rmware and software updates. Registering the software will also enable Aiphone Corporation to easily retrieve the License Key for the IS-SOFT should it ever be misplaced.