  Phase 3 with iterated transmission of DLE EOT and IDs due to no response or invalid 
response 
If  the  sending  station  receives  no  response  or  any  invalid  response  from  the  receiving  station  in 
response  to  the  sent  sequence  of  DLE  EOT  and  IDs,  then  it  iterates  sending  of  the  sequence  at 
0.5-second intervals up to 60 times. 
If the sending station receives a sequence of DLE ACK and IDs before sending the sequence of DLE 
EOT and IDs 60 times, then it terminates the message transmission normally and releases the data link. 
 
 Abnormal termination of phase 3 
  If the sending station receives no sequence of DLE ACK and IDs from the receiving station within 0.5 
second  from  the  60th  sequence  of  DLE  EOT  and  IDs,  then  it  aborts  the  message  transmission 
abnormally and releases the data link. 
 