 Abnormal termination of phase 2 (Abort of phase 2) 
If the sending station receives no sequence of DLE ACK and IDs from the receiving station after sending 
a sequence of DLE ENQ and IDs 59 times in succession, then it sends a sequence of DLE EOT and IDs 
to the receiving station after 0.5 second from the 59th sequence of DLE ENQ and IDs and then aborts 
this transmission abnormally. 
 
 
Phase 3: Release of Data Link 
 Normal phase 3 
The sending station transmits a sequence of DLE EOT and IDs to the receiving station. Upon receipt of 
a sequence of DLE ACK and IDs from the receiving station, the sending station terminates the message 
transmission normally and releases the data link. 
 