3.3  Basic Communications Specifications 
and Parameters 
3.3.1  Basic Communications Specifications 
Listed  below  are  the  communications  specifications  when  the  BHT  exchanges  data  with  a  host 
computer through the IrDA interface or direct-connect interface. 
 
Synchronization 
Transmission Speed 
Transmission Code 
Transmission Bit Order 
Vertical Parity 
 
 Synchronization 
For accurate data transaction, it is very important to synchronize the transmission between the sender 
and receiver. To do this, it is required to previously define the bit order and position, the character length, 
and the beginning and end of the character to be transmitted. 
The start-stop synchronization is an asynchronous system which synchronizes each character as a unit; 
that is, it externally adds start and stop bits to the leading and trailing bit positions of the character to be 
transmitted,  respectively.  A  clock  starts  counting  on  receiving  the  start  bit  and  it  falls  into  a 
non-communication state on receiving the stop bit. The number of the stop bits is selectable (1 or 2 bits). 
 Transmission Speed 
Maximum number of bits to be transmitted per second. Expressed in bps (bits per second). 
 IrDA Interface Communications Range 
The IrDA interface's maximum effective range is 15 cm (5.9 in.) with the IR beam within a 10° angle of 
divergence. 
To communicate via the CU-8000, put the BHT on the CU-8000. 
 Switching Time between Sending and Receiving on IrDA Interface 
The  IrDA  interface  should  satisfy  the  following  requirements  in  switching  between  sending  and 
receiving: 
(1)  Within 10 ms from completion of sending, the IrDA interface should become ready to receive. 
(2)  After 10 ms or more from completion of receiving, the IrDA interface should start sending. 
IrDA Interface 
Start-stop 
2400, 9600, 19200, 38400, 
57600, or 115200 bps 
JIS 8-bit codes 
LSB (Least significant bit) first 
None 
Chapter 3  Communications Operations of BHT 
Direct-connect Interface 
300, 600, 1200, 2400, 4800, 9600, 
19200, 38400, 57600, or 115200 bps 
JIS 7- or 8-bit codes 
Even, odd, or none 
97