3.6. Others
(a) Do the jumper settings (IRQ, I/O address) on the JOG
board agree with the DVEdit software settings?
(b) Is the Targa driver installed?
(c) Is the SCSI driver installed?
(d) Is the display driver changed for Targa?
(e) Is DVEdit installed?
( f ) Is the font installed in Windows?
(g) Is the font additionally registered in DVEdit? (Register
it with "Font Setup" on the "Special" panel.)
(h) Has the device been set up? (Set up "Reference",
"VTR Type", "Input/Output Type", etc. with "Device
Setup" on the "Special" panel.)
After checking all of the above, confirm again that the
installation procedures have been completed. Then,
check on the "Windows NT Diagnostic Program" panel
that IRQ assignments have been properly made on the
panel shown below. IRQ, etc. may not always agree with
the example shown below.
Type of Board
Administrator Display
SCSI
aic78xx
Targa
DVRNTDRV
Jog
Jog
53
Quantity Shown
2
1
1