Panasonic AY-RP500 Installation Manual page 21

Nonlinear editing system control panel kit
Hide thumbs Also See for AY-RP500:
Table of Contents

Advertisement

Note on I/O port settings:
Make sure that the following I/O ports do not
overlap so that the JOG board can perform 10-
bit address decoding.
JOG board
230H
230- 23F
630- 63F
240H
240- 24F
640- 64F
330H
330- 33F
730- 73F
340H
340- 34F
740- 74F
• Generally speaking, 0240-024F and 0F40-0F4F are
often allocated to a Sound Blaster board.
4. Insert the JOG board into the ISA slot that is the far-
thest away from the CPU. At this point, insert each
special cable securely into the LTC/REF connector
and the RS422-1 connector. After positioning them,
secure the cover in place using the screws.
5. Store the screws and cover that were removed in a
safe place.
6. Turn on the power and start up Windows NT.
7. Install the driver for the JOG board.
The JOG board driver is included in the CD-ROM of
the software package. Refer to the user's manual of
the software package for details on installation.
When the software package is installed, the driver
will be installed at the same time.
screens for the IRQ and I/O port will appear. Select
the same values as the jumper pin settings. When
installation ends, the Setup Complete window
appears.
Select "Yes, I want to restart my computer now".
(When this is selected,
Click
Finish
. The computer will restart.
8. When Windows NT has restarted, click
From Programs in the Start Menu, click
"Administrative Tools"
p
Diagnostics". The program starts up.
19
Other devices
A30- A3F
E30- E3F
A40- A4F
E40- E4F
B30- B3F
F30- F3F
B40- B4F
F40- F4F
( : Number from 0 to F)
The setting
is displayed.)
Start
.
Windows NT
9. The Windows NT Diagnostics window appears.
Click the "Resources" label.
appears.
(Refer to the diagram below)
10. Confirm that the AY-RP500 board (JOG board) IRQ ,
I/O port are the same number that was set with the
jumper. "Jog" indicates the AY-RP500 board.
Note: For the following cases, modify the jumper set-
tings for the JOG board's IRQ and the I/O port,
and reinstall the JOG driver:
•"Jog" display cannot be found in the release list.
•The JOGPAD and RS422 control functions do not
work with an application.
The Windows NT Diagnosis
The resource list

Advertisement

Table of Contents
loading

Table of Contents