Figure 56 Advanced Setup

The following table describes the labels in this screen.

Table 47 Advanced Setup

LABEL
AT Command
Strings
Dial
Drop
Answer
Drop DTR When
Hang Up
AT Response
Strings
CLID
Called ID
Speed
Call Control
Chapter 7 WAN Screens
DESCRIPTION
Type the AT Command string to make a call.
Type the AT Command string to drop a call. "~" represents a one second wait, for
example, "~~~+++~~ath" can be used if your modem has a slow response time.
Type the AT Command string to answer a call.
Select this check box to have the ZyWALL drop the DTR (Data Terminal Ready)
signal after the "AT Command String: Drop" is sent out.
Type the keyword that precedes the CLID (Calling Line Identification) in the AT
response string. This lets the ZyWALL capture the CLID in the AT response string
that comes from the WAN device. CLID is required for CLID authentication.
Type the keyword preceding the dialed number.
Type the keyword preceding the connection speed.
ZyWALL 70 User's Guide