2-1-4. Configuring the Management Agent of 24 Gigabit L2 Managed
Switch
We offer you three ways to startup the switch management function. They
are RS-232 console, CLI, and Web. Users can use any one of them to monitor and
configure the switch. You can touch them through the following procedures.
Section 2-1-4-1: Configuring the Management Agent of 24 Gigabit L2 Managed
Switch through the Serial RS-232 Port
Section 2-1-4-2: Configuring the Management Agent of 24 Gigabit L2 Managed
Switch through the Ethernet Port
Note: Please first modify the IP address, Subnet mask, Default gateway and DNS
through RS-232 console, and then do the next.
17
User Manual
Publication date: January, 2006
Revision A2
User Manual

2-1-4-1. Configuring the Management Agent of 24 Gigabit L2 Managed Switch

through the Serial RS-232 Port
To perform the configuration through RS-232 console port, the switch's serial
port must be directly connected to a DCE device, for example, a PC, through
RS-232 cable with DB-9 connector. Next, run a terminal emulator with the default
setting of the switch's serial port. With this, you can communicate with the switch.
In the switch, RS-232 interface only supports baud rate 57.6k bps with 8 data
bits, 1 stop bit, no parity check and no flow control.
RS-232 DB-9 Connector
RS-232
RS-232 cable with female
DB-9 connector at both ends
Terminal or Terminal Emulator
To configure the switch, please follow the procedures below:
Find the RS-232 DB-9 cable with female DB-9 connector bundled.
1.
Normally, it just uses pins 2, 3 and 7. See also Appendix B for more
details on Null Modem Cable Specifications.
Attaches the DB-9 female cable connector to the male serial RS-232
2.
DB-9 connector on the switch.
3.
Attaches the other end of the serial RS-232 DB-9 cable to PC's serial
port, running a terminal emulator supporting VT100/ANSI terminal with
The switch's serial port default settings. For example,
Windows98/2000/XP HyperTerminal utility.
Note: The switch's serial port default settings are listed as follows:
Baud rate
Stop bits
Data bits
Parity
Flow control
When you complete the connection, then press <Enter> key. The login
4.
prompt will be shown on the screen. The default username and
password are shown as below:
Username = admin
Publication date: January, 2006
Revision A2
18
AC Line 100-240V 50/60 Hz
24 Gigabit L2 Managed Switch
Default IP Setting:
IP address = 192.168.223.100
Subnet Mask = 255.255.255.0
Default Gateway =
192.168.223.254
Fig. 2-7
57600
1
8
N
none
Password = admin