Characteristics - Panasonic KX-TD816 Installation Manual

Digital super hybrid system
Hide thumbs Also See for KX-TD816:
Table of Contents

Advertisement

1.5
Specifications
1.5.2

Characteristics

KX-TD816
Station Loop Limit
Minimum Leakage Resistance
Maximum Number of Station Instruments per Line
Ring Voltage
Primary Power
Central Office Loop Limit
Environmental Requirements
Hookswitch Flash Timing Range
KX-TD1232
Station Loop Limit
Minimum Leakage Resistance
KX-T7220/KX-T7230/KX-T7235/KX-T7250/KX-T7020/KX-
T7030/KX-T7033/KX-T7050/KX-T7055/KX-T7130 .....40 ohms
Single Line Telephone/KX-T7051/KX-T7052
Doorphone................................................20 ohms
15 000 ohms
1 for KX-T7220, KX-T7230, KX-T7235,
KX-T7250, KX-T7130, KX-T7020, KX-T7030,
KX-T7033, KX-T7050, KX-T7055, KX-T7051,
KX-T7052 or single line telephone
2 by Parallel or eXtra Device Port Connection of a
proprietary telephone and a single line telephone
70 Vrms at 25 Hz depending on the Ringing Load
Service Unit
KX-TD816BX
KX-TD816HK/ML/NL/NZ
KX-TD816C
1 600 ohms max.
0 – 40 °C / 32 – 104 °F, 10 – 90%
84 – 1 000 milliseconds for KX-TD816NL
204 – 1 000 milliseconds for the other systems
KX-T7220/KX-T7230/KX-T7235/KX-T7250/KX-T7020/KX-
T7030/KX-T7033/KX-T7050/KX-T7055/KX-T7130 .....40 ohms
Single Line Telephone/KX-T7051/KX-T7052
Doorphone................................................20 ohms
15 000 ohms
.............600 ohms including set
Primary Power
115 / 200 / 220 / 240 VAC,
50 / 60 Hz, 1 A max.
220 – 240 VAC, 50 / 60 Hz,
1 A max.
120 VAC, 60 Hz, 1 A max.
.............600 ohms including set
System Outline
1-13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-td1232dbKx-td816bKx-td1232Kx-td1232bKx-td1232d