1.4 Specifications — KX-TDA100/KX-TDA200
1.4.2

Characteristics

Terminal Equipment Loop Limit •
Minimum Leakage Resistance
Maximum Number of Extension
Instruments per Line
Ring Voltage
Trunk Loop Limit
Hookswitch Flash/Recall
Timing Range
BRI Cards Internal ISDN Mode
Door Opener Current Limit
Paging Terminal Impedance
MOH (Music on Hold) Terminal
Impedance
32
Installation Manual
PT: KX-T7600 series: 90
SLT: 600
including set
Doorphone: 20
CS: 130
; PT-interface CS: 65
15 000
minimum
1 for PT or SLT
2 by Parallel or eXtra Device Port connection of a PT and an SLT
3 by Digital eXtra Device Port connection of two DPTs and an SLT
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
1600
maximum
24 ms to 2032 ms
Supply Voltage: 40 V
Power Supply: 4.5 W per 1 line, 10 W per 4 lines (BRI4)
4.5 W per 1 line, 20 W per 8 lines (BRI8)
Power Supply Method: Phantom Power Supply
24 V DC/30 V AC, 1 A maximum
600
10 000
; all other DPTs/APTs: 40