Specifications; General Description; Characteristics - Panasonic KX-NCP500GR Service Manual

Pure ip-pbx
Table of Contents

Advertisement

3 Specifications

3.1.

General Description

Control Bus
Communication Bus
Switching
Power Input
Power Consumption (when fully mounted)
Maximum Power Failure Tolerance
Memory Backup Duration
Dialling
Mode Conversion
Ring Frequency
Trunk Loop Limit
Operating Environment
Conference Call Trunk
Music on Hold (MOH)
Paging
Serial Interface Port
RJ45 Port
Extension Connection Cable
Dimension
Weight (when fully mounted)
3.2.

Characteristics

Terminal Equipment Loop Limit
Minimum Leakage Resistance
Maximum Number of Extension
Instruments per Line
Ring Voltage
Trunk Loop Limit
Hookswitch Flash/Recall Timing Range
BRI Cards Internal ISDN Mode
Door Opener Current Limit
External Relay Current Limit
External Sensor Current Limit
Paging Terminal Impedance
MOH (Music on Hold) Terminal Impedance
Original bus (16 bit, 8 MHz,10 megabytes per second)
H.100 bus conformity (1024 time slot)
Non-blocking
100 V AC to 130 V AC; 1.0 A/200 V AC to 240 V AC; 0.6 A; 50Hz/60 Hz
51 W (240 V: 122 VA, 200 V: 113 VA, 130 V: 100 VA, 100 V: 92 VA)
300 ms
7 years
Trunk
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialling
DP-DTMF, DTMF-DP
20 Hz/25 Hz (selectable)
1600 Ω maximum
0 °C to 40 °C
Temperature
Humidity
10%to 90%
From 10 x 3-party conference call to 4 x 8-party conference call
1 port (Level Control: -6 dB to +6 dB per 3 dB)
MOH1: Selectable Internal/External Music Source port
Internal
Level Control: -6 dB to +3 dB per 3 dB
External
1 port (Volume Control: -15 dB to +6 dB per 3 dB)
RS-232C
1 (max 115.2 kbps)
MNT Port
1 (for PC connection)
LAN Port
1 (for LAN connection)
SLT
DPT
APT
PT-interface CS
PT-interface CS (High-density)
DSS Consoles and Add-on Key Module
430 mm (W) x 88 mm (H) x 340 mm (D)
(17 in x 3 1/2 in x 13 3/8 in)
Under 7 kg (15.4 lb.)
• PT: KX-DT300/KX-T7600 series DPT: 90 Ω; all other DPTs/APTs:40 Ω
• SLT: 600 Ω including set
• Doorphone: 20 Ω
• CS: 65Ω
15000 Ω maximum
1 for PT or SLT
2 by Parallel or eXtra Device Port connection of an APT/DPT and an SLT
3 by Digital eXtra Device Port connection of 2 DPTs and an SLT
75 Vrms at 20 Hz/25 Hz depending on the Ringing Load
1600 Ω maximum
24 ms to 2032 ms
Supply Voltage: 40 V
Power Supply (BRI2): 4.5 W per 1 line, 9 W per 2 lines
Power Supply Method: Phantom Power Supply
24 V DC/30 V AC, 1 A maximum
24 V DC/30 V AC, 1 A maximum
Power to the external sensor is provided from the EIO4 card and must be grounded through
the EIO4 card. For the connection diagram, refer to EIO4 Card (KX-TDA0164). The PBX
detects input from the sensor when the signal is under 100Ω.
600 Ω
10000 Ω
1 pair wire (T, R)
1-pair wire (D1, D2) or
2-pair wire (T, R, D1, D2)
2-pair wire (T, R, D1, D2)
1-pair wire (D1, D2)
4-pair wire (D1, D2)
1-pair wire (D1, D2)
7
KX-NCP500GR

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-ncp1000gr