Konica Minolta DF-606 Service Manual page 221

Hide thumbs Also See for DF-606:
Table of Contents

Advertisement

Theory of Operation Ver1.0 Jun.2005
B. Gate /Up
The gate /Up [5] switches the paper path of the paper that was conveyed to the upper conveyance path by the
gate /Lw. The gate /Up is set to the paper path to the exit side [3] when the gate solenoid /Up (SD2) [4] turns
OFF [6]. The gate /Up is set to the paper path [2] to the 1st folding stopper [1] when SD2 turns ON [7].
[1]
1st folding stopper
[2]
Conveyance path to the 1st folding stopper
[3]
Conveyance path to the exit side
[4]
Gate solenoid /Up (SD2)
C. Operation timing
(1) Z-folding mode
In the Z-folding mode for the all paper size, the gate solenoid /Lw (SD1) and the gate solenoid /Up (SD2) turn
ON when the paper edge sensor board (PESB) detects the leading edge of the paper [1], and then the gate /Lw
is set to the upper conveyance path and the gate /Up is set to the conveyance path to the 1st folding stopper.
SD1 and SD2 turn OFF [2] a specified period of time after the last paper turns OFF the exit sensor (PS9).
Paper edge sensor board (PESB)
Exit sensor (PS9)
Gate solenoid /Lw (SD1)
Gate solenoid /Up (SD2)
[1]
Leading edge of the paper detected by the
paper edge sensor board (PESB)
[1]
4. CONVEYANCE SECTION
[5]
Gate /Up
[6]
SD2 turned OFF
[7]
SD2 turned ON
[2]
Gate solenoid /Lw (SD1) and gate solenoid /
Up (SD2) turned OFF
15kvt2c005na
[2]
15kvt2c006na
11