GNS-530/W Maintenance Mode Entry:
GNS-530 configuration data is accessed from the GNS-530/W Maintenance Mode settings which is entered via holding
ENTR button on 530/W bezel during power application.
GNS-530/W Page Navigation:
Use the inner right knob on the GNS-530/W to scroll through the maintenance mode pages. Each clockwise click of the
knob selects the next page. On pages where selectable fields exist, a push of the right knob will produce a flashing cursor.
The outer right knob moves through the fields on a page when there is a flashing cursor. Twist the inner right knob
clockwise to see a list of choices. Use the inner right knob to scroll through the list of choices and press the "ENT" button
to select the desired choice.
IFD5XX Maintenance Mode Entry:
IFD5XX configuration data is accessed via Mx Mode which is entered by starting the IFD with a USB Fob already
installed or selecting the AUX page, SYS tab, ensuring that the "Select" LSK = Software, and then pressing the "Download
Logs" LSK, followed by the "Confirm" LSK. These tables contain all the data that can be entered at time of installation to
ensure the IFD5XX is properly configured. There are additional setup options that selectable by the pilot (Display
Options on AUX Setup tab) that are not documented here.
IFD5XX Page Navigation:
To reach the IFD pages on which this data is to be entered, select the CONFIG tab in Maintenance Mode. Use the outer
right knob to select the page – each clockwise click of the outer right knob selects the next page in the list. Push the right
knob in to generate a cursor and then use the outer right knob to select an individual field with the cursor. Then twist the
inner right knob to scroll through the selectable options for that field and push in the right knob when done with each
field selection.
For retrofit installations (those installations in which an IFD5XX is replacing a GNS-530/W), enter the data in the
following tables/menu pages from the corresponding fields recorded below in the GNS-530/W tables on the left side of
each page. Repeat for each retrofit IFD5XX.
For new installations (those installations in which an IFD5XX is NOT replacing a GNS-530/W), select and record the
appropriate settings for each configuration page per the descriptive material below each table.
600-00299-000