1. INSTALLATION

1.1 INSTALLATION REQUIREMENTS

1.1.1 ENVIRONMENT

1.
Temperature Range: 10°C to 32°C (50°F to 89.6°F)
2.
Humidity Range: 15% to 80% RH
3.
Ambient Illumination: Less than 2,000 lux (do not expose to direct sunlight)
4.
Ventilation: 3 times/hr/person
5.
Do not put the machine in areas that get sudden temperature changes. This includes:
Areas directly exposed to cool air from an air conditioner
Areas directly exposed to heat from a heater.
6.
Do not put the machine in areas that get exposed to corrosive gas.
7.
Do not install the machine at locations over 2,500 m (8,125 ft.) above sea level.
8.
Put the machine on a strong, level base. (Inclination on any side must be no more than
5 mm.)
9.
Do not put the machine in areas with strong vibrations.

1.1.2 MACHINE LEVEL

Front to back: Within 5 mm (0.2") of level
Right to left: Within 5 mm (0.2") of level