Smart Organizing Monitor (Printer Model)
Item
Duplex Tray
Fuser SC Reset
Fuser SC Detect
Reset Transfer Unit
Life Counter
Trans. Belt Adjust
"*" indicates the factory default value.
G165/G166/G167/G181/G183/G184
Selections
Horizontal (-15 to +15)
step
Vertical (-15 to +15) step
On/Off
5-34
Remarks
1.32mm per step. Range is -5mm to
+5mm.
If the machine settings are reset to
the factory defaults, this value does
not change.
The printer will exit the energy saver
state after this setting is changed.
0.24mm per step. Range is -3.6mm
to +3.6mm
If the machine settings are reset to
the factory defaults, this value does
not change.
The printer will exit the energy saver
state after this setting is changed.
This button is for resetting an SC
related with the fusing errors.
If On, the engine detects SC559. If
Off, the engine does not detect
"Fusing SC Reset."
Resets the transfer unit life counter.
When you click the [Trans. Belt
Adjust] button, the transfer belt
adjustment is done. This calibrates
the motor speed to match the length
of the new transfer belt.