Image Transfer
6.6.4 ITB (IMAGE TRANSFER BELT) CLEANING UNIT
The ITB cleaning blade [A] in the cleaning unit removes remaining toner on the image
transfer belt after image transfer to the paper. The toner collection coil [B] moves the
collected waste toner to the outlet for the waste toner bottle.
The ITB cleaning unit has a shutter mechanism at the outlet for the waste toner bottle.
When the ITB unit is removed, the shutter closes the outlet to prevent waste toner from
falling.
SM
6-35
G165/G166/G167/G181/G183/G184