Vert.Bypass
Horiz.Dup.Back
Vert.Dup.Back
Reset Count
Resets counters to factory defaults.
Clear Count
Clears the Scanner and Jam Counters.
Resets the maintenance counter for the fusing unit.
Replace Fuser
This item appears only when the fusing unit life is almost expired or
has expired.
Scan Maintenance
Mono
Sets the monochrome compression type for scanning.
Compression
MH (Default)/ MR/ MMR
Setting
ADF Main Reg.
Regist Adjust
ADF Sub Reg.
SM
Adjusts the vertical registration for the bypass tray.
If the machine settings are reset to the factory
defaults, this value does not change.
[-15 to 15 / 0 (Default) / 0.3 mm/step]
Adjusts the horizontal registration for the back side
in duplex mode. If the machine settings are reset
to the factory defaults, this value does not change.
[-15 to 15 / 0 (Default) / 4 mm/step]
Adjusts the vertical registration for the back side in
duplex mode. If the machine settings are reset to
the factory defaults, this value does not change.
[-15 to 15 / 0 (Default) / 0.3 mm/step]
Adjusts the ADF Scan main-scan registration.
(G181 doesn't support this.)
[-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step]
Adjusts the ADF Scan sub-scan registration.
(G181 doesn't support this.)
[-2.0 to 2.0 / 0 (Default)/ 0.1 mm/step]