Ricoh G165 Service Manual page 192

G165; g166; g167; g181; g183; g184
Hide thumbs Also See for G165:
Table of Contents

Advertisement

Service Menu (MF Model)
TX Settings
Overseas Comm
Mode Settings
G165/G166/G167/G181/G183/G184
Number of CNG cycles to be detected
CNG Cycles
This setting is only effective for FAX/TAD mode.
[1.5 Cycle (Default)/ 2.0 Cycle]
Determines the period when tones from the line
Tone Sound
are monitored.
Monitoring
[No Monitoring/ Up To Phase B (Default)/ All TX
Phases]
Pressing the Stop/Clear key can stop the current
Stop/Clear key
receiving operation. Received data is lost.
[Not Functional (Default)/ Functional]
Sets the off-hook detection threshold.
Off-Hook Level
[10V (Default)/ 15V/ 20V/ 25V]
Sets the redial interval when Tx fails.
Redial Interval
[5 Min/ 6 Min]
Sets the number of redials when Tx fails.
Redialings
[2 times/ 3 Times/ 4 Times/ 5 Times]
This sets the machine to ignore a DIS signal sent
Overseas
from the called station once in a sending
Comm Mode
operation.
[Off (Default)/ Ignore DIS Once]
If this setting is set to "On", the machine detects
the CNG signal after the line is connected. If it is
Minimum Time
set to "Off", the machine detects the CNG signal
Length
as long as the line is connected.
[100 Ms/ 200 Ms/ 300 Ms/ 400 Ms (Default)]
5-44