Heat & Glo RED60 Installation Manual page 23

Installation and appliance setup
Hide thumbs Also See for RED60:
Table of Contents

Advertisement

Top Vent - Horizontal Termination - (continued)
V
Minimum
1
2 ft.
610 mm
3 ft.
914 mm
4 ft.
1.2 m
V
+ V
+ H
+ H
= 70 ft. (21.3 m) Maximum
1
2
1
2
H
2
Figure 4.26
Note: Must have 24 inches minimum
vertical vent prior to attaching any
elbow to the appliance.
Note: PVI-DVP can be located in any
position except V
.
1
WARNING! Risk of fi re and burns!
DO NOT install PVI-DVP with the
access panel facing upward. Over-
heating may occur.
4 Elbows
V
Minimum
1
2 ft.
610 mm
3 ft.
914 mm
4 ft.
1.2 m
TOTAL V + TOTAL H = 60 ft. (18.3 m) Maximum
Top Vent - Horizontal Termination
Venting with 3 elbows
V
+ V
+ H
+ H
Maximum
1
2
1
2
40 ft.
12.2 m
50 ft.
15.2 m
70 ft.
21.3 m
WARNING! Risk of fi re and burns!
DO NOT install PVI-DVP with the
access panel facing upward. Over-
heating may occur.
V
2
Top Vent - Horizontal Termination
Venting with more than 3 elbows
Note: Use DVP Series
components only.
Total V + Total H Maximum
30 ft.
9.1 m
40 ft.
12.2 m
60 ft.
18.3 m
Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13
Note: Must have 24 inches minimum
vertical vent prior to attaching any
elbow to the appliance.
Note: PVI-DVP can be located in any
position except V
.
1
H
1
V
Minimum
1
2 ft.
610 mm
3 ft.
914 mm
4 ft.
1.2 m
Total V + Total H = 50 ft. (15.2 m) Maximum
V
Minimum
1
2 ft.
610 mm
3 ft.
914 mm
4 ft.
1.2 m
Total V + Total H = 40 ft. (12.2 m) Maximum
Note: Use DVP Series
components only.
V
1
5 Elbows
Total V + Total H Maximum
30 ft.
9.1 m
40 ft.
12.2 m
50 ft.
15.2 m
6 Elbows
Total V + Total H Maximum
10 ft.
3.0 m
20 ft.
6.0 m
40 ft.
12.2 m
23