Heat & Glo RED60 Installation Manual page 19

Installation and appliance setup
Hide thumbs Also See for RED60:
Table of Contents

Advertisement

FAN
HARNESS
HARNESS
THERMO SNAP DISC
HARNESS
6VDC TRANSFORMER
JUMPER
JUNCTION BOX
VALVE
Figure 4.19 RED60 PVI-DVP with IntelliFire Plus Pilot Ignition Wiring Diagram
Installation Inspection
1. Follow safety inspection procedures recommended by
national, provincial, and/or local codes.
2. Be certain all electrical connections are properly made
and secure.
3. Visually inspect the vent system and determine that
there is no fl ue gas spillage, blockage or restriction,
leakage, corrosion or other unsafe defi ciencies.
4. Place the fi replace in operation and determine that the
burner and power vent are operating properly. The
main burner should show no signs of fl oating, lifting, or
fl ashbacks.
WARNING: If any unsafe condition is determined when
inspecting the installation and operation of the fi replace
and Power Vent, the equipment should be shut off. Cor-
rections MUST be made before the equipment is put into
continuous operation.
Vacuum Switch Orientation
WARNING! Risk of Fire and Explosion! Install vacuum
switch on a vertical plane. Failure to follow instructions could
result in fi re or explosion.
If the PVI is mounted in a vertical position, the vacuum
switch needs to be moved. To do this, loosen and remove
the two nuts currently using to secure it to the inside wall
of the PVI. Move and secure the vacuum switch onto the
adjacent wall using the two bolts that are sticking out of
the surface. See Figure 4.20 for the location on the vert-
APPLIANCE ON/OFF CONTROL
MALE/FEMALE
WIRE ASSEMBLY
WALL SWITCH
JUMPER WIRE
ELECTRICAL
ACCESS KNOCKOUT
HI LIMIT SWITCHES
GREEN
GREEN
JUMPER
JUMPER
JUMPER
ORANGE
Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13
INTERMITTENT
PILOT IGNITOR
SENSOR
IGNITER
WIRE
WIRE
WHITE
ORANGE
8K1-PVI
AUX300
MODULE
IPI WIRE
HARNESS
GROUND TO
FIREPLACE CHASSIS
cal plane in regards to horizontal or vertical orientation.
The vacuum switch must be installed on a vertical plane.
If the PVI is orientated horizontally in the vent run, install
the vacuum switch in location "A" noted in Figure 4.20. If
the PVI is orientated vertically in the vent run, install the
vacuum switch in location "B" in Figure 4.20. Follow in-
structions on label attached inside the PVI. Remove the
label as directed. See Figure 4.21 for the switch and wire
orientation.
PVI VERTICAL
Figure 4.20 Vacuum Switch Location - Horizontal/Vertical Orientation
TO FAN OUTLET
ON JUNCTION
BOX
ACCESSORY
CABLE
TO PVI-DVP
PVI HORIZONTAL
A
VACUUM
SWITCH
B
19