INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
NOTICE: DO NOT discard this manual!
Model(s):
This appliance may be installed as an OEM
installation in manufactured home (USA
only) or mobile home and must be installed
in accordance with the manufacturer's
instructions and the Manufactured Home
Construction and Safety Standard, Title 24
CFR, Part 3280 in the United States, or the
Standard for Installation in Mobile Homes,
CAN/CSA Z240 MH Series, in Canada.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certifi ed kit is used.
Installation Manual
Installation and Appliance Setup
Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of this
or any other appliance.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
WARNING
DO NOT TOUCH GLASS
NEVER ALLOW CHILDREN
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with this
appliance and shall be installed.
In the Commonwealth of Massachusetts installation must be
performed by a licensed plumber or gas fi tter.
See Table of Contents for location of additional Commonwealth
of Massachusetts requirements.
HOT GLASS WILL
CAUSE BURNS.
UNTIL COOLED.
TO TOUCH GLASS.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo RED40

  • Page 1 See Table of Contents for location of additional Commonwealth of Massachusetts requirements. gases, unless a certifi ed kit is used. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 2: Table Of Contents

    C. Active Convection Technology ..... 26  = Contains updated information. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 3: Installation Standard Work Checklist

    Comments: Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective action needed _____________________________________________________________________________________ _________________________________________________________________________________________________ Comments Communicated to party responsible ____________________ by ______________________on ___________ (Builder / Gen. Contractor/) (Installer) (Date) 2155-982B 11/13 = Contains updated information. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 4: Product Specifi C And Important Safety Information

    34,000 25,000 RED40 (0-2000 FT) or near sinks. RED40ST CANADA (LP) 31,500 23,000 (2000-4500 FT) Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 6: Getting Started

    Call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and/or gas control which has been under water. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 7: Framing And Clearances

    1187 13-3/16 10-3/4 50-1/8 1273 25-1/16 42-3/4 1086 18-5/8 48-1/8 1222 9-1/16 3-3/4 4-3/4 1-1/2 8-1/2 42-15/16 1090 18-1/8 14-1/2 Figure 3.1 Appliance Dimensions - RED40 Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 8 1321 13-3/16 50-1/8 1273 10-3/4 42-3/4 1086 25-1/16 18-1/8 48-1/8 1222 9-1/16 3-3/4 4-3/4 1-1/2 8-1/2 42-15/16 1090 17-1/8 14-1/2 Figure 3.2 Appliance Dimensions - RED40ST Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 9: Clearances To Combustibles

    TOP VENT ONE 90° ELBOW Inches 60-3/8 85-3/8 24-1/8 18-3/4 See Section D. Figure 5.6 & 5.7 Millimeters 1533 1270 2168 Figure 3.3 Appliance Locations RED40 Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 10: Constructing The Appliance Chase

    fl oor. However, this fi replace can be elevated off the fl oor provided that the fi replace is properly supported by framing materials and the ceiling clearances are maintained. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 11: Minimum Framing Dimensions

    Opening Rear of to Ceiling Floor Flooring Appliance (Vent Pipe) (Height) (Depth) (Width) Appliance Inches 46-3/4 17-1/4 50-1/4 Millimeters 1187 1276 Figure 3.7. Clearances to Combustibles-RED40ST Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 12: Termination Location And Vent Information

    Over 18/12 to 20/12 ..........7.5 Over 20/12 to 21/12 ..........8.0 * 3 foot minimum in snow regions Figure 4.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 13: Chimney Diagram

    2 sides beneath the fl oor. • Vinyl protection kits are suggested for use with vinyl siding. Figure 4.3 Minimum Clearances for Termination Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 14: Approved Pipe

    See Figure 4.4. • Horizontal runs of vent do not require vertical rise; horizontal runs may be level. Vertical 8-1/2 in. Horizontal Figure 4.4 Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 15 1829 mm 18 ft. 5486 7 ft. 2134 mm 21 ft. 6401 8 ft. 2438 mm 24 ft. 7315 = 63 ft. (19.2 m) Maximum Figure 4.5 Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 16 2743 mm 4 ft. 1219 mm 12 ft. 3658 mm = 63 ft. (19.2 m) Maximum = 23 ft. (7.1 m) Maximum INSTALLED HORIZONTALLY Figure 4.6 Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 17 12 ft. 3658 mm 5 ft. 1524 mm 15 ft. 4572 mm = 63 ft. (19.2 m) Maximum = 23 ft. (7.1 m) Maximum Figure 4.7 Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 18 fl ame height. If the vent confi guration has a total ver- tical of 20-50 feet, an exhaust restrictor may be needed. The exhaust restrictor can be located in the appliance manual bag. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 19 = 23 ft. (7.1 m) Maximum Note: 12 inches minimum vertical is Note: Use DVP Series required prior to attaching any elbow components only. to the appliance. Figure 4.10 Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 20 MAXIMUM VERTICAL FROM DROP APPLIANCE NOTE: Maximum total vent run= Total vertical vent run + Total horizontal vent run Figure 4.12 Power Vent Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 21: Vent Clearances And Framing

    * Shows center of vent framing hole for top venting. The center of the hole is one (1) in. (25.4 mm) above the center of the horizontal vent pipe. Figure 5.2 Wall Penetration Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 22: Install The Ceiling Firestop

    BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 5.4 Installing the Attic Shield Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 23: Install Attic Insulation Shield

    • Bend all tabs inward 90º around the top of the shield. These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to maintain air space clearance. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 24: Appliance Preparation

    Remove all four screws and gently lift the panel off the appliance avoiding contact with the non-combustible board if possible. BOTTOM PANEL SCREW LOCATIONS Figure 6.1 Location of Fiberglass Rope Ring Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 25: Securing And Leveling The Appliance

    DUCT COLLAR ASSEMBLY POSSIBLE LOCATIONS FOR VENT TERMINATION OF ACTIVE CONVECTION TECHNOLOGY TERMINATION INTO INTERIOR ROOM Figure 6.2 Proper Positioning, Leveling And Securing Of An Appliance Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 26: Active Convection Technology

    ZIP TIE CONVECTION (INCLUDED WITH FLEX DUCT) AIR DUCT 4 INCH FLEX DUCT DETAIL A FAN BRACKET ASSEMBLY Figure 6.5. Active Convection Technology Duct Venting Specifi cations. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 27: Venting And Chimneys

    Use screws no longer than 1/2 INCORRECT in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. Figure 7.4 Seams Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 28: Assemble Slip Sections

    • Only outer pipes are sealed, sealing the inner fl ue is not required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 29: Disassemble Vent Sections

    Figure 7.10 • Pull carefully to separate the pieces of pipe. Figure 7.9 Rotate Seams for Disassembly Figure 7.10 Align and Disassemble Vent Sections Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 30: Vertical Termination Requirements

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 7.12. • Caulk the overlap seam of any exposed pipe sections that are located above the roof line. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 31: Horizontal Termination Requirements

    • Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section. Important Notice: Heat shields may not be fi eld constructed. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 32 1-1/2 IN. (38 MM) MIN. HEAT SHIELD OVERLAP WALL SHIELD FIRESTOP SLIP SECTION CAN BE EXTENDED INNER VENT SHEATHING OUTER VENT INTERIOR EXTERIOR Figure 7.15 Venting Through the Wall Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 33: Electrical Information

    In the event that the junction box may need to be ac- cessed or installed after fi nish methods have been ap- plied, access is possible by removing the valve assembly See Figure 9.2. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 34: Wiring Requirements

    Figure 8.4. The valve does not move. JUNCTION OPTIONAL REMOTE CONTROL MODULE VALVE INSTALLED ON RIGHT JUNCTION VALVE CONTROL MODULE OPTIONAL REMOTE Figure 8.4. Controls Location Diagram Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 35 VAC is required at junction box. ACCESS KNOCKOUT (Wire colors subject to change) Figure 8.5 IntelliFire Pilot Ignition (IPI) Wiring Diagram with Wall Switch or Remote Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 36: Optional Led Lighting Circuit

    ORANGE IGNITION PLUG IN MODULE 3 VAC GREEN BLUE NEUTRAL YEL/ORG/GRN WHITE/CLEAR JUNCTION BOX YEL/ORG YELLOW ORG/GRN PURPLE YEL/GRN LIGHT BLUE Figure 8.7 LED Wiring Diagram Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 37: Active Convection Blower Replacement

    fi rebox opening. See Figure 8.14. Figure 8.10 Lifting Base Pan Up and Out. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 38 Remove blower and attached mounting bracket from the appliance. See Figure 8.16. Figure 8.18 Removal of Mounting Bracket from Blower Figure 8.16 Blower Removal Through Hole in Firebox Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 39 11. Connect electrical cord to the junction box. fan points toward the interior of the appliance. Arrows are highlighted by white boxes in Figure 8.20. Figure 8.20. Arrow Indicates Direction of Air Flow Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 40: Gas Information

    1. Remove the glass rock media or the porcelain from the • Close the manual shutoff valve BEFORE interior fi rebox. pressure testing gas line at test pressures equal to or less than 1/2 psig. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 41: Gas Connection

    2000 feet and 4500 feet. Above 4500 feet, GAS SHUT OFF VALVE GAS SHUT OFF VALVE consult local gas utility. Figure 9.4 Gas Fitting Access Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 42: Air Shutter Setting

    Figure 9.5 Air Shutter Air Shutter Settings RED40/RED40ST GRANITE KIT 1/16 in. 1/4 in. LIGHT KIT 1/16 in. 1/4 in. PORCELAIN KIT 1/16 in. 1/4 in. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 43: Finishing

    Inadequate air space may cause overheating and fi re. Ensure that the one inch back clearance and one inch side clearances are maintained. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 44 If desired fi nishing includes a painted wall, 100% acrylic latex with compatible primer is recommended around this appliance. Oil-based or standard acrylic paints may dis- color due to heat exposure. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 45 Specifi c requirements for each method if installation are described below and on the following pages of this section. Figure 10.5 Non-Combustible Finish Material Diagram for 0-1 Inch Thick Overlap Fit Method Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 46 1-3/16 IN. 1-1/2 IN. = CLEARANCE FROM VIEWING AREA TO NON-COMBUSTIBLE FINISHING MATERIAL (INSIDE FIT METHOD) Figure 10.7 Noncombustible Surface Finishing Material 0-4 Inches Thick-Inside Fit Method Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 47: Mantel And Wall Projections

    TO CEILING measurements in inches. MAX. MIN. MEASUREMENTS FROM TOP EDGE OF THE FIRESCREEN DOOR ASSEMBLY Figure 10.9 Minimum Vertical and Maximum Horizontal Dimensions of Non-Combustibles Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 48: Mesh Fronts

    Engage these tabs in the slot of the brackets. MESH BRACKETS MESH FRAME ASSEMBLY HANGING TABS MESH FRAME ASSEMBLY Figure 10.11. Mesh Front Installation. Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 49: Appliance Setup

    A mesh front is included with the RED40 and RED40ST. For installation instructions, see section 10.C. GLASS SIDE SUPPORT GLASS CLIP GLASS TAB Figure 11.1 Fixed Glass Assembly Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 50: Reference Materials

    (38 mm) (254 mm) 14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 51 117 mm Length DVP-TRAP 5-3/8 in. 9-3/8 in. Trap2 Horizontal Termination Cap 137 mm 238 mm DVP-TRAP2 DVP-TRAP1 DVP-TRAPK2 DVP-TRAPK1 DVP-HPC2 DVP-HPC1 Figure 12.2 DVP vent components Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 52 9-1/2 in. 26 in. (352 mm) (241 mm) 660 mm 14 in. (356 mm) DVP-HSM-B Extended Heat Shield DRC-RADIUS Cap Shield Figure 12.3 DVP vent components Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 53 5-3/4 to 8-3/8 in. 140 mm 213 mm 146 to 213 mm 3° 87° 10-1/2 in. 267 mm 10-7/8 in. 276 mm Figure 12.4 DVP vent components Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 54 9-3/16 IN. (233 mm) 13-5/8 IN. 16-11/16 IN. 16-11/16 IN. (346 mm) 424 mm (424 mm) 12-1/2 IN. SLP-LPC (318 mm) SLP Low Profi le Cap Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...
  • Page 55: Accessories

    Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer, please visit www.heatnglo.com. Printed in U.S.A. - Copyright 2013 Heat & Glo • RED40, RED40ST Installation Manual • 2155-980 Rev. C • 11/13...