Heat & Glo RED60 Installation Manual page 22

Installation and appliance setup
Hide thumbs Also See for RED60:
Table of Contents

Advertisement

Top Vent - Horizontal Termination - (continued)
V
Minimum
V
1
2 ft.
610 mm
3 ft.
914 mm
4 ft.
1.2 m
V
+ H
+ H
= 70 ft. (21.3 m) Maximum
1
1
2
WARNING! Risk of fi re and burns!
DO NOT install PVI-DVP with the
access panel facing upward. Over-
heating may occur.
H
2
Figure 4.25
22
Top Vent - Horizontal Termination
Venting with 2 elbows
+ H
+ H
Maximum
1
1
2
50 ft.
15.2 m
60 ft.
18.3 m
70 ft.
21.3 m
INSTALLED
HORIZONTALLY
Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13
Note: Must have 24 inches minimum
vertical vent prior to attaching any
elbow to the appliance.
Note: PVI-DVP can be located in any
position except V
.
1
H
1
Note: Use DVP Series
components only.