Installation and appliance setup
Hide thumbs Also See for RED60:
Table of Contents

Advertisement

Note: AN 8 X 16 inch
framed hole is required in
front of the access panel.
This hole may be covered
with an open air louvered
cover.
Figure 4.11 Mount PVI-DVP to Chase
Figure 4.12 and Figure 4.13 show the proper installation
of the PVI-DVP if a louvered register is being used to
provide free air.
ADJUST BRACKET
TO SPECIFIED DEPTH
SHEETROCK
Figure 4.12 PVI-DVP Mounted with Fresh Air Access
CHASE
APPLIANCE
Note: If the access
cover is solid, the
1/2 in. clearance
should change to a
minimum of 2 in.
1/2 IN. MAX. FROM
BACK OF OPEN
AIR COVER
LOUVERED OR
OPEN AIR WALL
COVER
Heat & Glo • RED60 Installation Manual • 2159-980 Rev. D • 11/13
DECORATIVE
OPEN AIR COVER
NOTE: COVER MUST BE AT
LEAST 50% OPEN AIR.
Figure 4.13
For additional scenarios to attach the PVI, the optional
mounting brackets can be used. They can be secured to
the side brackets on the PVI using wing nuts (supplied).
The brackets can be attached anywhere along these des-
ignated holes. See Figure 4.14 and 4.15.
Figure 4.14
8 x 16
OPENING IN WALL
17