Retry Function (Pr. 65, Pr. 67 To Pr. 69) - Mitsubishi FR-E 500 Instruction Manual

Fr-e 500 series transistorized inverter
Hide thumbs Also See for FR-E 500:
Table of Contents

Advertisement

4.2.25 Retry function (Pr. 65, Pr. 67 to Pr. 69)

Pr. 65 "retry selection"
Pr. 67 "number of retries at alarm occurrence"
Pr. 68 "retry waiting time"
Pr. 69 "retry count display erasure"
When any protective function (major fault) is activated and the inverter stops its output,
the inverter itself resets automatically and performs retries. You can select whether
retry is made or not, alarms reset for retry, number of retries made, and waiting time.
Parameter
Factory
Number
Setting
65
67
68
69
<Setting>
Use Pr. 65 to select the protective functions (major faults) which execute retry.
Errors Reset
for Retry
Display
0
"
E.OC1
"
E.OC2
"
E.OC3
"
E.OV1
"
E.OV2
"
E.OV3
"
E.THM
"
E.THT
E.FIN
"
E. BE
"
E. GF
E.LF
"
E.OHT
"
E.OLT
"
E.OPT
"
E. PE
E.PUE
E.RET
E.CPU
E.
6
E.
7
"
Note:
indicates the retry items selected.
Setting Range
0
0 to 3
0
0 to 10, 101 to 110
1 s
0.1 to 360 s
0
0
Setting
1
2
"
"
"
"
"
"
3
"
"
"
"
"
"
101
PARAMETERS

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents