Mitsubishi FR-E 500 Instruction Manual page 63

Fr-e 500 series transistorized inverter
Hide thumbs Also See for FR-E 500:
Table of Contents

Advertisement

( 3 ) Combined operation mode 1 (Pr. 79 "operation mode selection" = 3)
The start signal is an external signal.
The frequency setting signal is set using the optional control
panel or parameter unit.
Preparation
! Start signal ...............Switch, relay, etc.
! Operation unit...........Control panel (FR-PA02
! Connection cable......Refer to (1) PU operation mode.
! FR-E5P (option) .......Refer to (1) PU operation mode.
( 4 ) Combined operation mode 2 (Pr. 79 "operation mode selection" = 4)
The start signal is entered from the operation command key
of the optional control panel.
The frequency setting signal is set using the external
frequency setting signal.
Preparation
! Frequency ..................0 to 5V, 0 to 10V or 4 to 20mA DC
setting signal
! Operation unit.............Control panel (FR-PA02
! Connection cable........Refer to (1) PU operation mode.
! FR-E5P (option) .........Refer to (1) PU operation mode.
( 5 ) Communication operation mode
(Pr. 79 "operation mode selection" = 0 or 1)
Communication operation can be performed by connecting a personal computer and
the PU connector with the RS-485 communication cable.
The inverter setup software is available as an FR-E500 inverter start-up support
software package.
Preparation
! Connection cable.......................... Connector: RJ45 connector
! Personal computer
! RS-485, RS-232C converter......... To be prepared when the communication port of the
parameter unit (FR-PU04)
signals from an external
potentiometer or from outside the
inverter
parameter unit (FR-PU04)
Cable: Cable conforming to EIA568
(e.g. 10BASE-T cable)
personal computer has RS-232C specifications.
49
) or
-02
) or
-02
3