! You can also set the detection of the frequency used exclusively for reverse rotation.
This function is effective for switching the timing of electromagnetic brake operation
between forward rotation (rise) and reverse rotation (fall) during vertical lift operation etc.
Parameter
Number
42
43
<Setting>
Refer to the figure below and set the corresponding parameters:
! When Pr. 43 ≠ 9999, the Pr. 42 setting applies to forward rotation and the Pr. 43
setting applies to reverse rotation.
! Assign the terminal used for FU signal output with any of Pr. 190 to Pr. 192 (output
terminal function selection).
Refer to page 150 for Pr. 190 to Pr. 192 (output terminal function selection).
Note: Changing the terminal assignment using Pr. 190 to Pr. 192 may affect the
other functions. Make setting after confirming the function of each terminal.
Pr. 44, Pr. 45 '
' Refer to Pr. 7.
' '
Pr. 46 '
' Refer to Pr. 0.
' '
Pr. 47 '
' Refer to Pr. 3.
' '
Pr. 48 '
' Refer to Pr. 9
' '
Factory
Setting
Setting
Range
6Hz
0 to 400Hz
0 to 400Hz,
9999
9999
Forward
rotation
Output signal
FU
OFF
Remarks
9999: Same as Pr. 42 setting
Pr.42
Reverse
rotation
ON
ON
OFF
91