Automatic Restart After Instantaneous Power Failure (Pr. 57, Pr. 58) - Mitsubishi FR-E 500 Instruction Manual

Fr-e 500 series transistorized inverter
Hide thumbs Also See for FR-E 500:
Table of Contents

Advertisement

4.2.22 Automatic restart after instantaneous power failure
(Pr. 57, Pr. 58)
Pr. 57 "restart coasting time"
Pr. 58 "restart cushion time"
! You can restart the inverter without stopping the motor (with the motor coasting)
when power is restored after an instantaneous power failure.
Parameter Number
57
58
<Setting>
Refer to the following table and set the parameters:
Parameter
Number
0
57
58
Factory Setting
9999
1.0 s
Setting
0.1K to 1.5K
0.5 s coasting time
2.2K to 7.5K
1.0 s coasting time
Waiting time for inverter-triggered restart after power is restored
from an instantaneous power failure. (Set this time between 0.1 s
0.1 to 5 s
and 5 s according to the inertia moment (J) and torque of the
load.)
9999
No restart
Normally the inverter may be run with the factory settings. These
0 to 60 s
values are adjustable to the load (inertia moment, torque).
Instantaneous power
failure (power failure) time
Power supply
(R, S, T)
STF(STR)
Motor speed
(r/min)
Inverter output
frequency
(Hz)
Inverter output
voltage
(V)
Coasting time
Pr. 57 setting
Setting Range
0 to 5 s, 9999
9999: No restart
0 to 60 s
Description
Generally use this setting.
Restart
voltage
rise time
Pr. 58 setting
95
PARAMETERS
Remarks

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents