Monitor Display (Pr. 52, Pr. 54, Pr. 158) - Mitsubishi FR-E 500 Instruction Manual

Fr-e 500 series transistorized inverter
Hide thumbs Also See for FR-E 500:
Table of Contents

Advertisement

4.2.20 Monitor display (Pr. 52, Pr. 54, Pr. 158)

Pr. 52 "control panel/PU main display
data selection"
Pr. 54 "FM terminal function selection"
Pr. 158 "AM terminal function selection"
You can select the signal displayed on the control panel (FR-PA02-
(FR-PU04) main display screen and the signal output to the FM terminal (100V class,
200V class) and AM terminal (400V class).
<100V class, 200V class>
! Output terminal: Terminal FM (pulse train output)
! Output signal selection: Pr. 54 "FM terminal function selection"
<400V class>
! Output terminal: Terminal AM (analog output)
! Output signal selection: Pr. 158 "AM terminal function selection"
Parameter
Factory
Number
Setting
52
54
158
<Setting>
Set Pr. 52, Pr. 54 and Pr. 158 in accordance with the following table:
Signal Type
Unit
Output
Hz
frequency
Output current
A

Output voltage

Alarm display
Actual
10h
operation time
Setting
Range
0
0, 23, 100
0
0, 1, 2
0
0, 1, 2
Parameter Setting
Pr. 52
Control
PU main
panel
monitor
LED
0/100
0/100
0/100
0/100
0/100
0/100
0/100
0/100
23
23
92
Related parameters
Pr. 37 "speed display"
Pr. 55 "frequency monitoring
reference"
Pr. 56 "current monitoring
reference"
Pr. 171 "actual operation hour
meter clear"
Pr. 900 "FM terminal calibration"
Pr. 901 "AM terminal calibration"
Pr. 54
Pr. 158
FM
AM
terminal
terminal
0
0
1
1
2
2
×
×
×
×
PARAMETERS
)/parameter unit
02
Full-Scale Value of
FM, AM Level Meter
Pr. 55
Pr. 56
400V or 800V


4

Hide quick links:

Advertisement

Table of Contents
loading