Pan, Tilt, and Zoom (PTZ) Setup

Configuring an ACUIX Dome for PTZ Use

110
2.
On the Serial Devices tab, select the values shown in
Figure 6-15
Communication Settings for Intellibus on the Serial Devices Tab
Table 6-3
Intellibus Settings for ACUIX Domes
Communications
Baud Rate
Stop Bits
Data Bits
Parity Bits
1.
Run a
Maintenance
Session.
2.
Click the Video tab.
3.
Click PTZ. For information about enabling and configuring a PTZ dome, see
Tab Settings for PTZ
on page 96.
4.
Select an ACUIX dome.
5.
In Port Attributes, enter values for Baud Rate, Stop Bits, Data Bits and Parity (as
shown in
Table
6-3).
6.
Do not use the same Camera Address for two ACUIX domes that share the same port.
7.
Repeat
step 4
to
step 6
Shortcut for selecting all of
the items listed in the table
Value
38400
1
8
None
for each ACUIX dome in your system.