AMAX 2100 / 3000 / 4000
02 - System Armed
The output is operated in the following cases:
The output is reset in the following cases:
If the output time is set to 000, the output will continue until the system is disarmed.
03 - System Alarm
This output is operated when an alarm occurs.
The output is reset in the following cases:
In case of a new alarm, the output time will be reset.
If the output time is set to 000, the output will continue until the zone is restored or the
system is disarmed.
04 - System Alarm (audible and silent)
This output is operated in case of an audio alarm of the system:
This output also operates in case of a silent alarm of the system:
The output is reset in the following cases:
In case of a new alarm, the output time will be reset.
If the output time is set to 000 and the alarm siren sounds time to 0, the output will continue
until the alarm output is reset or the system is disarmed by entering your code + [3] [2] + [#].
The output of the following system alarms is only one second:
05 - External AWAY Siren
The output is operated in the following cases:
(No output is operated when the system is disarmed.)
Bosch Sicherheitsysteme GmbH
The system is armed.
The programmed output time ends.
The system is armed after a system reset.
The system operated the arm command. (After the exit time ends.)
The system is disarmed.
The programmed output time ends.
The system is disarmed and alarm is reset.
The programmed output time ends.
Zone (alarm or tamper) programmed to disable zone silent alarm
System tamper / DX2010 tamper / keypad tamper
Keypad alarm (emergency alarm, fire alarm, medical aid alarm)
Zone (alarm or tamper) programmed to enable zone silent alarm.
The alarm is reset.
The system is armed.
The system is disarmed.
Alarm siren test
Pacing (tamper / alarm / reset)
Key switch arming or locking key switch disarming
The system is in AWAY mode and a zone intruder alarm (intruder alarm = instant / interior
instant / delay / interior delay / delay exit / interior delay exit / follower / interior
follower / 24h (can be silenced) / fire (can be silenced) / technical alarm (can be
silenced)) occurs.
The system is in AWAY mode and a tamper alarm occurs.